This Kit Includes:
• 1 × Samsung EHS Monobloc Air-to-Water Heat Pump Outdoor Unit AE050RXYDEG/EU (5kW, Single Phase, R32)
• 1 × Samsung Pre-Plumbed DHW Cylinder ACL-180PW (180L cylinder with integrated 50L buffer)
• MIM control kit pre-installed (cylinder package)
• G3 compliance kit (expansion vessel, cold water groupset and tundish)
• Pre-plumbed hydraulic components ready for installation
• Installation and user documentation• Includes MIM-E03CN (1-zone) control, with optional control kit MIM-E03FN (2-zone) which can be selected on this webpage if required for zoning/control preference
Pre-Plumbed DHW Cylinder Package with Integrated Buffer for Samsung EHS 5kW Monobloc
This Samsung EHS package combines the compact AE050RXYDEG/EU 5kW monobloc heat pump with the ACL-180PW pre-plumbed hot water cylinder, creating a tidy, installer-friendly solution for domestic hot water and heat pump system integration. It’s particularly well suited to homes and small properties where space is limited, but you still want a more generous hot water store than a typical entry-level cylinder.
The ACL-180PW includes an integrated 50L buffer tank, which supports stable flow rates and helps reduce heat pump cycling as heating demand changes through the day. The cylinder arrives with key hydraulic components already integrated, giving a cleaner plant-room finish and reducing on-site build time. With a high-gain coil designed for heat pump operation and a 3kW immersion provision for DHW support when required, this is a practical, future-ready setup for efficient year-round heating and hot water performance.
Key Product Features:
• 5kW monobloc air-to-water inverter heat pump using R32 refrigerant
• Pre-plumbed slimline cylinder package for faster, cleaner installation
• 180L hot water cylinder capacity with integrated 50L buffer for improved stability
• High-gain smooth coil design to support efficient heat pump hot water recovery
• Buffer tank helps reduce short-cycling and improves system control
• G3 compliance components included for UK unvented installation requirements
• Colour-coded tapping collars for clearer, faster pipework connections
• 3kW immersion heater provision for DHW top-up and support cycles
• Integrated filtration and metering components to support long-term system reliability
Technical Specifications:
Heat Pump Outdoor Unit: AE050RXYDEG/EU
Type: Monobloc air-to-water inverter heat pump
Nominal Output: 5kW
Power Supply: 220–240V~50Hz, 1Ph
Refrigerant: R32
Refrigerant Charge: 1.0 kg
Flow Temperature Range (Heating): 15°C to 65°C
Sound Power Level: 61 dB(A)
Minimum Flow Rate: 7
Maximum Flow Rate: 48
Dimensions (H × W × D): 798 × 880 × 310 mm
Weight: 58.5 kg
Pre-Plumbed DHW Cylinder: ACL-180PW
Cylinder / Buffer Capacity (L/L): 180 / 50
Usable Water Volume V40 (L): 260
Actual DHW Volume (L): 168
Coil Size (m²): 2.0
Coil Rating (kW): 25.2
Standing Heat Loss: 1.39 kW/24h (58 W)
Energy Efficiency Class: C
Booster Heater (DHW): 3kW @ 230V AC
Dimensions (H × Ø): 1751 mm × 540 mm
Weight (Empty / Full): 85 kg / 253 kg
DHW Expansion Vessel: 19 L
Primary PWM Circulating Pump: Wilo Para 7-50/iPWM
3-Port Diverter Valve (28mm): Honeywell V4044C1288
Integrated Items: flow meter, magnetic filter, DHW temperature sensor, filling loop and fill/flush point
Quick Zone Controller Difference: MIM-E03CN (1-zone) vs MIM-E03FN (2-zone):
-
MIM-E03CN (1-zone): Designed to control one heating circuit (one target flow temperature / one schedule). Typically used for a single system type, e.g. radiators only or underfloor only. Usually supplied with a standard wired controller (referenced with MWR-WW10N).
-
MIM-E03FN (2-zone): Designed to control two independent heating circuits, each with its own control logic and schedule (commonly radiators + underfloor heating). This is the one that typically includes a larger touch controller and Wi-Fi capability, making it better for mixed applications and more detailed control.
MIM-E03CN (1-zone) Included Parts:
MIM-E03FN (2-zone / “AI Home” style control) Included Parts:
-
7” colour touchscreen “AI Home” panel
-
MWR-WW10N wired controller
-
Extra sensors (DHW / mixing valve / electric heater sensors)
-
PV control cable
-
Flow sensor assembly (with pipe/fittings)
Disclaimer:
Specifications may be subject to change based on manufacturer updates. Images are for illustrative purposes only.