Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Warm Air Suspended Gas Unit Heaters

Powrmatic NVx40 Suspended Gas Unit Heater 40Kw/135000Btu 240V~50Hz

  • Powrmatic NVx40 Suspended Gas Unit Heater 40Kw/135000Btu 240V~50Hz
  • Powrmatic NVx40 Suspended Gas Unit Heater 40Kw/135000Btu 240V~50Hz
  • Powrmatic NVx40 Suspended Gas Unit Heater 40Kw/135000Btu 240V~50Hz
  • Powrmatic NVx40 Suspended Gas Unit Heater 40Kw/135000Btu 240V~50Hz
  • Powrmatic NVx40 Suspended Gas Unit Heater 40Kw/135000Btu 240V~50Hz

Powrmatic NVx40 Suspended Gas Unit Heater 40Kw/135000Btu 240V~50Hz

£2,612.80 £2,177.33 (ex. VAT)
Stock Status: In Stock

Includes:

1 x Powrmatic NVx40
1 x Controller


The Powrmatic NVX Warm Air Suspended Gas Unit Heater from Powrmatic provides efficient and cost effective heating solutions for industrial and commercial properties.  The NVx range of gas fired unit heaters comprises 11 models with outputs ranging from 15 kW to 140 kW. The heaters are typically installed directly into the space to be heated with ducted applications satisfied using the centrifugal fan option. Suitable for natural or LPG gases, heaters can be specified/arranged for on/off, high/low or modulated heat outputs. A comprehensive range of control and modular duct components ensures total system flexibility in terms of applications offering heating only and ventilation only.

Warm air heating provides an efficient, flexible and cost effective solution for the heating of most industrial and commercial buildings.Powrmatic have been a leading manufacturer of warm air heating products for more than sixty years. Integrity of design and quality of manufacture are characteristics inherent in each and every product. NVx Gas Unit Heaters are designed for suspended off the floor space saving location and clean lines with a fully housed burner. Capable of being operated in room sealed or conventional flue mode flues can discharge either vertically or horizontally saving expensive roof works. Models suitable for natural gas or lpg firing. All heaters are finished with a durable epoxy powder coat paint finish which is stove hardened. Combustion Chamber/Heat Exchanger tube manipulated assembly designed to combine thermal efficiency with long lasting service life. Life cycle tested and warranted for ten years. Fuel Efficiency and Low Carbon Emissions underpin the heater design with all models meeting current Part L2B Building Regulations and meeting the exacting criteria of the Government’s Enhanced Capital Allowance scheme.

Time and Temperature Controls fully compatible with NVx heaters can be optionally supplied so as to provide automatic operation. Control stations are supplied loose for convenient low level mounting with customers selecting either the easy to set Powrtrol, or the code protected optimised start MC200 controller. Both control systems include as standard, day thermostat, frost protection thermostat, programmable time switch and fan only switching to facilitate summer air movement. 

 

Key Product Features:
 

• Natural Gas & LPG
• Space saving ‘off-floor’ mounting
• Axial freeblowing, centrifugal fan and duct heater options
• Room sealed combustion circuit
• Time & temperature compatible control stations
• ECA compliant for lower fuel consumption and 
carbon emissions
• Summer air movement
• Extended guarantee
• 10 year heat exchanger warranty


Specification:

Model

40

Output

40

Input (nett CV)

43.48

Airflow Volume

NVx F / C / V

1.00

Duo

N/A

NVx D

Min

0.83

Max

1.11

Airflow

Throw

NVx F

21.0

NVx Duo

N/A

Fan Static

NVx C

236

Electrics

Supply

Standard

230/1/50

Optional

400/3/50 (Centrifugal Unit Only)

NVx F

Motor

0.27

Start

2.40

Run

1.20

NVx C

Motor

1.10

Start

18.50

Run

6.40

Fuel

Connection

¾”

Minimum Inlet Pressure

Nat Gas

17.5

LPG

37.0

Consumption

Nat Gas

4.60

LPG

1.78

Mounting Height

NVx F/Duo Crossflow

Min

3.00

Max

5.00

NVx V

Downflow

Min

4.00

Max

7.00

Overall Dims

NVx F

Height

760

Width

1000

Depth

905

Install Clearance

NVx F

Top

200

LH Side

200

RH Side

1000

Rear

400

Flue

Diameter

100

Max Length

Flue Only

12

Room Sealed

6

Combustion Air Spigot

100

Noise Levels

NVx F

58

NVx V

68

Nett Weight

NVx F

115

NVx C

168.5



Notes:

Fuel Consumption and input figures based upon nett calorific values as follows:

  • Natural Gas (G20) nett CV 34.02 MJ/m3
  • Propane (G31) nett CV 88.00 MJ/m3
  • Heaters have efficiency levels which meet with the minimum heater efficiency requirements of UK Part L Building Regulations
  • Air handling data is assessed at room ambient conditions
  • Throw figures provide the distance to the point where the terminal velocity degrades to 0.25m/s
  • Dimensions and clearance data in the table above refer to NVx F units only - for NVx C and NVx D data refer to the dimensions page and/or the installation instructions
  • Noise levels are applicable to standard NVx F models and are measured 5m from appliance in a typical installation situation.
  • Motor kW, run and start amps apply to standard electrical supply as stated.  For optional data contact sales office
  • Connection of combustion air duct is not required for ‘flue only’ applications
  • The NVx Duo throw dimension is the effective combined throw measurement
  • It is the responsibility of the installing contractor to ensure that duct work is correctly sized and balanced when installing NVx Centrifugal units
  • Installer guidance notes on rear page


PDF Data Sheet:





Installation Service On Request
Not yet reviewed
Write an online review and share your thoughts with other shoppers!