Warm Air Suspended Gas Heaters Home / Heating / Warm Air Suspended Gas Heaters / Powrmatic NVx15 Suspended Gas Unit Heater 15Kw/50000Btu 240V~50Hz Powrmatic NVx15 Suspended Gas Unit Heater 15Kw/50000Btu 240V~50Hz Powrmatic NVx15 Suspended Gas Unit Heater 15Kw/50000Btu 240V~50Hz £2,268.88 £1,890.73 (ex. VAT) Stock Status: Sold Out Concentric Vertical Terminal Kit: Not Required Concentric Vertical Terminal Kit (+£401.23) Concentric Horizontal Terminal Kit: Not Required Concentric Horizontal Terminal Kit (+£221.33) Sorry, this item is out of stock Information Reviews MODEL REPLACED BY LX15 Includes: 1 x Powrmatic NVx15 1 x Controller The Powrmatic NVX Warm Air Suspended Gas Unit Heater from Powrmatic provides efficient and cost effective heating solutions for industrial and commercial properties. The NVx range of gas fired unit heaters comprises 11 models with outputs ranging from 15 kW to 140 kW. The heaters are typically installed directly into the space to be heated with ducted applications satisfied using the centrifugal fan option. Suitable for natural or LPG gases, heaters can be specified/arranged for on/off, high/low or modulated heat outputs. A comprehensive range of control and modular duct components ensures total system flexibility in terms of applications offering heating only and ventilation only. Warm air heating provides an efficient, flexible and cost effective solution for the heating of most industrial and commercial buildings.Powrmatic have been a leading manufacturer of warm air heating products for more than sixty years. Integrity of design and quality of manufacture are characteristics inherent in each and every product. NVx Gas Unit Heaters are designed for suspended off the floor space saving location and clean lines with a fully housed burner. Capable of being operated in room sealed or conventional flue mode flues can discharge either vertically or horizontally saving expensive roof works. Models suitable for natural gas or lpg firing. All heaters are finished with a durable epoxy powder coat paint finish which is stove hardened. Combustion Chamber/Heat Exchanger tube manipulated assembly designed to combine thermal efficiency with long lasting service life. Life cycle tested and warranted for ten years. Fuel Efficiency and Low Carbon Emissions underpin the heater design with all models meeting current Part L2B Building Regulations and meeting the exacting criteria of the Government’s Enhanced Capital Allowance scheme. Time and Temperature Controls fully compatible with NVx heaters can be optionally supplied so as to provide automatic operation. Control stations are supplied loose for convenient low level mounting with customers selecting either the easy to set Powrtrol, or the code protected optimised start MC200 controller. Both control systems include as standard, day thermostat, frost protection thermostat, programmable time switch and fan only switching to facilitate summer air movement. Key Product Features: • Natural Gas & LPG • Space saving ‘off-floor’ mounting • Axial freeblowing, centrifugal fan and duct heater options • Room sealed combustion circuit • Time & temperature compatible control stations • ECA compliant for lower fuel consumption and carbon emissions • Summer air movement • Extended guarantee • 10 year heat exchanger warranty Specification: Model 15 Output kW 15 Input (nett CV) kW 16.00 Airflow Volume NVx F / C / V m3/s 0.39 Duo m3/s N/A NVx D Min m3/s 0.31 Max m3/s 0.42 Airflow Throw NVx F m 10.0 NVx Duo m N/A Fan Static NVx C Pa 145 Electrics Supply Standard V/ph/Hz 230/1/50 Optional V/ph/Hz 400/3/50 (Centrifugal Unit Only) NVx F Motor kW 0.12 Start amp 0.80 Run amp 0.54 NVx C Motor kW 0.25 Start amp 4.50 Run amp 1.50 Fuel Connection BSP/Rc ¾” Minimum Inlet Pressure Nat Gas mbar 17.5 LPG mbar 37.0 Consumption Nat Gas m3/h 1.69 LPG m3/h 0.65 Mounting Height NVx F/Duo Crossflow Min m 2.5 Max m 3.0 NVx V Downflow Min m Max m Overall Dims NVx F Height mm 540 Width mm 1000 Depth mm 892 Install Clearance NVx F Top mm 200 LH Side mm 200 RH Side mm 1000 Rear mm 400 Flue Diameter mm Ø 80 Max Length Flue Only m 12 Room Sealed m 6 Combustion Air Spigot mm Ø 80 Noise Levels NVx F dB(A) 54 NVx V dB(A) 64 Nett Weight NVx F kg 71.5 NVx C kg 106.5 Notes: Fuel Consumption and input figures based upon nett calorific values as follows: Natural Gas (G20) nett CV 34.02 MJ/m3 Propane (G31) nett CV 88.00 MJ/m3 Heaters have efficiency levels which meet with the minimum heater efficiency requirements of UK Part L Building Regulations Air handling data is assessed at room ambient conditions Throw figures provide the distance to the point where the terminal velocity degrades to 0.25m/s Dimensions and clearance data in the table above refer to NVx F units only - for NVx C and NVx D data refer to the dimensions page and/or the installation instructions Noise levels are applicable to standard NVx F models and are measured 5m from appliance in a typical installation situation. Motor kW, run and start amps apply to standard electrical supply as stated. For optional data contact sales office Connection of combustion air duct is not required for ‘flue only’ applications The NVx Duo throw dimension is the effective combined throw measurement It is the responsibility of the installing contractor to ensure that duct work is correctly sized and balanced when installing NVx Centrifugal units Installer guidance notes on rear page PDF Data Sheet: Installation Service On Request Write an online review and share your thoughts with other shoppers! Be the first to review this product Related Products Olympus JetHeat OLY-J3/1 Industrial Electric Fan Heater with Thermostat 3Kw/12000Btu 240V~50Hz £90.00 £75.00 (ex. VAT) (2) Kroll Mobile Plant Heater HM200 Diesel Burner Space Heater 170kW £36,720.00 £30,600.00 (ex. VAT)