Panasonic Air Conditioning Wall Mounted Inverter+ Heatcharge KIT-VZ12-SKE Nanoe 3.5kW/12000Btu A+++ 220-240V~50Hz Install Kit
This Kit Includes:
1 x Panasonic Air Conditioning Wall Mounted Inverter+ Heatcharge CS-VZ12SKE Nanoe 3.5kW/12000Btu A+++ 220-240V~50Hz
1 x Panasonic Air Conditioning Outdoor Condensing Unit Heat pump Inverter+ Heatcharge CU-VZ12SKE 3.5kW/12000Btu A+++ 220-240V~50Hz
1 x Remote Controller Ir
1 of Panasonic Ir remote controller (option of wired CZ-RD514C controller)
15 Meters x 1/4 inch coil pipe.
15 Meters x 3/8 inch coil pipe.
8 x Isoline (1/4 x 3/8) insulation 2 meter lengths Black
8 x Isoline (3/8 x 3/8) insulation 2 meter lengths Black
1 x Wall Bracket Outdoor Unit BJ TYPE 2 60KG LOAD
The Panasonic Heat-charge has the capacity to store heat on the outdoor unit which allows heating to start quickly just after turning on the heat pump. It also ensures maximum comfort and heat in the house even during defrost operation as Heat charge also stores heat to prevent cool air during defrost. ECONAVI builds-in a new Sunlight Detection technology to adjust output ideally thereby giving you the best comfort at anytime whilst saving energy. Furthermore, the Nanoe-G revolutionary air-purifying system utilises nano technology fine particles to remove and deactivate 99% of both airborne and adhesive micro-organisms like bacteria, viruses and mould. These technological breakthrough's make the Panasonic VE Inverter+ HeatCharge unit a individual system with unique features not matched by any other on the world air conditioning market. Ideal for cold locations.
Key Product Features:
- Can be installed on existing R22 piping
- Works up to -30 °C
- Energy Charge System
- Heat storage unit which realizes NON-STOP heating and fast heating function
- Maximum efficiency and comfort with Econavi sunlight detection
- Nanoe-G air purifying system, 99 % effective on both airborne and adhesive mould, viruses and bacteria
- Super Quiet! Only 23 dB(A), equivalent to night-time in the country
- More powerful airflow to quickly reach the desired temperature.
- Powerful mode
- Uniform dispersion of airflow
- Automatic vertical airflow control
- Hot start mode, increased comfort on heat pump mode, no cool airflow when process starts
- Automatic restart after power cut
- Removable, washable panel
- Self-diagnosis function
- Real time clock with dual ON&OFF timer
- User friendly infrared remote control
- Optional wired weekly timer with 6 settings per day and 42 settings per week
- Connectivity function (indoor unit equipped with PCB port which can be connected to a outside network
Technical Specification:
KIT-VZ12-SKE
Indoor unit
|
|
|
CS-VZ12SKE
|
Power supply
|
|
V
|
230
|
Recommended fuse
|
|
A
|
16
|
Connection indoor / outdoor
|
|
mm²
|
4 x 1,5
|
Air flow
|
Cool / Heat (Hi)
|
m³/min
|
12,9 / 15,9
|
Sound pressure 4)
|
Cool (Hi / Lo / Q-Lo)
Heat (Hi / Lo / Q-Lo)
|
dB(A)
dB(A)
|
45 / 33 / 18
45 / 29 / 18
|
Dimension
|
H x W x D
|
mm
|
295 x 798 x 375
|
Net weight
|
|
kg
|
14,5
|
Outdoor unit
|
|
|
CU-VZ12SKE
|
Air flow
|
Cool / Heat (Hi)
|
m³/min
|
35,4 / 33,9
|
Sound pressure 4)
|
Cool / Heat (Hi)
|
dB(A)
|
50 / 50
|
Dimension 5)
|
H x W x D
|
mm
|
630 x 799 x 299
|
Net weight
|
|
kg
|
39,5
|
Piping diameter
|
Liquid pipe
Gas pipe
|
Inch (mm)
Inch (mm)
|
1/4 (6,35)
3/8 (9,52)
|
Pipe length range
|
|
m
|
3 ~ 15
|
Elevation difference (in / out)
|
|
m
|
12
|
Pipe length for additional gas
|
|
m
|
7,5
|
Additional gas amount
|
|
g/m
|
20
|
Refrigerant (R32) / CO Eq. kg / T 1,10 / 0,7425
Cool Min ~ Max °C -10 ~ +43
Cooling capacity
|
Nominal (Min - Max)
|
kW
|
2,50 (0,60 - 3,00)
|
SEER 1)
|
|
|
10,50 A+++
|
Pdesign (cooling)
|
|
kW
|
2,50
|
Input power
|
Nominal (Min - Max)
|
kW
|
0,43 (0,14 - 0,61)
|
Annual energy consumption 3)
|
|
kWh/a
|
83
|
Heating capacity
|
Nominal (Min - Max)
|
kW
|
3,60 (0,60 - 7,80)
|
COP 2)
|
|
W/W
|
5,63
|
Heating capacity at -7 °C
|
|
kW
|
5,00
|
COP at -7 °C 2)
|
|
W/W
|
2,07
|
SCOP 1)
|
|
|
6,20 A+++
|
Pdesign at -10 °C
|
|
kW
|
3,60
|
Input power
|
Nominal (Min - Max)
|
kW
|
0,64 (0,14 - 2,72)
|
Annual energy consumption 3)
|
|
kWh/a
|
812
|
1) Energy Label Scale from A+++ to D. 2) EER and COP calculation is based in accordance to EN14511. 3) The annual energy consumption is calculated in accordance to EU/626/2011. 4) The sound pressure of the indoor unit shows the value measured of a position of 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed. 5) Add 70 mm for piping port. 6) Tested by 3rd party laboratory, SP, according to EN14511:2013 and SP Method 1721, this temperature is not guaranteed by Factory.
These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.