Panasonic Air Conditioning U-14MF3E8 40.0 kW ECOi 3 pipe H/R Inv O/D R410a 3ph 415V
Key Product Features:
|
8HP
|
10HP
|
12HP
|
14HP
|
16HP
|
Outdoor Units
|
|
|
U-8MF3E8
|
U-10MF3E8
|
U-12MF3E8
|
U-14MF3E8
|
U-16MF3E8
|
|
Voltage
|
V
|
380 / 400 / 415
|
380 / 400 / 415
|
380 / 400 / 415
|
380 / 400 / 415
|
380 / 400 / 415
|
Power supply
|
Phase
|
|
Three Phase
|
Three Phase
|
Three Phase
|
Three Phase
|
Three Phase
|
|
Frequency
|
Hz
|
50
|
50
|
50
|
50
|
50
|
Starting current
|
A
|
1,00
|
1,00
|
1,00
|
2,00
|
2,00
|
External static pressure (Max)
|
Pa
|
80
|
80
|
80
|
80
|
80
|
Air volume
|
m/min
|
210
|
220
|
232
|
232
|
232
|
Sound pressure Normal mode
|
dB(A)
|
54,00
|
57,00
|
60,00
|
61,00
|
62,00
|
Silent mode 1 / 2
|
dB(A)
|
51,00 / 49,00
|
54,00 / 52,00
|
57,00 / 55,00
|
58,00 / 56,00
|
59,00 / 57,00
|
Sound power Normal mode
|
dB
|
76,00
|
78,00
|
81,00
|
82,00
|
82,00
|
Dimension H x W x D
|
mm
|
1842 x 1180 x 1000
|
1842 x 1180 x 1000
|
1842 x 1180 x 1000
|
1842 x 1180 x 1000
|
1842 x 1180 x 1000
|
Net weight
|
kg
|
261
|
262
|
286
|
334
|
334
|
Liquid pipe
|
Inch (mm)
|
3/8 (9,52) / 1/2 (12,70)
|
3/8 (9,52) / 1/2 (12,70)
|
1/2 (12,70) / 5/8 (15,88)
|
1/2 (12,70) / 5/8 (15,88)
|
1/2 (12,70) / 5/8 (15,88)
|
Piping connections 3) Discharge pipe
|
Inch (mm)
|
5/8 (15,88) / 3/4 (19,05)
|
3/4 (19,05) / 7/8 (22,22)
|
3/4 (19,05) / 7/8 (22,22)
|
7/8 (22,22) / 1 (25,40)
|
7/8 (22,22) / 1 (25,40)
|
Suction pipe
|
Inch (mm)
|
3/4 (19,05) / 7/8 (22,22)
|
7/8 (22,22) / 1 (25,40)
|
1 (25,40) / 1-1/8 (28,58)
|
1 (25,40) / 1-1/8 (28,58)
|
1-1/8(28,58)/1-1/4(31,75)
|
Balance pipe
|
Inch (mm)
|
1/4 (6,35)
|
1/4 (6,35)
|
1/4 (6,35)
|
1/4 (6,35)
|
1/4 (6,35)
|
Refrigerant (R410A)
|
kg / TCO Eq.
2
|
6,80 / 14,1984
|
6,80 / 14,1984
|
8,30 / 17,3304
|
8,30 / 17,3304
|
8,30 / 17,3304
|
Maximum allowable indoor / outdoor capacity ratio %
|
50 ~ 150
|
50 ~ 150
|
50 ~ 150
|
50 ~ 150
|
50 ~ 150
|
Cool Min ~ Max °C
|
-10 ~ +52
|
-10 ~ +52
|
-10 ~ +52
|
-10 ~ +52
|
-10 ~ +52
|
Operating range Heat Min ~ Max °C
|
-20 ~ +18
|
-20 ~ +18
|
-20 ~ +18
|
-20 ~ +18
|
-20 ~ +18
|
Simultaneous op. °C
|
-10 ~ +24
|
-10 ~ +24
|
-10 ~ +24
|
-10 ~ +24
|
-10 ~ +24
|
Cooling capacity
|
kW
|
22,40
|
28,00
|
33,50
|
40,00
|
45,00
|
EER 1)
|
W/W
|
5,11
|
4,72
|
3,91
|
3,70
|
3,49
|
SEER 2)
|
W/W
|
7,02
|
7,05
|
6,39
|
6,69
|
6,02
|
Running current cooling
|
A
|
7,16 / 6,80 / 6,55
|
9,90 / 9,41 / 9,07
|
3,19 / 13,20 / 12,70
|
18,20 / 17,30 / 16,70
|
21,30 / 20,20 / 19,50
|
Input power cooling
|
kW
|
4,38
|
5,93
|
8,57
|
10,80
|
12,90
|
Heating capacity
|
kW
|
25,00
|
31,50
|
37,50
|
45,00
|
50,00
|
COP 1)
|
W/W
|
5,25
|
5,17
|
4,51
|
4,21
|
4,17
|
SCOP 2)
|
W/W
|
4,85
|
4,25
|
4,27
|
4,13
|
3,81
|
Running current heating
|
A
|
7,78 / 7,39 / 7,12
|
10,20 / 9,66 / 9,31
|
13,40 / 12,80 / 12,30
|
18,10 / 17,20 / 16,50
|
20,00 / 19,00 / 18,30
|
Input power heating
|
kW
|
4,76
|
6,09
|
8,32
|
10,70
|
12,00
|
3-Pipe control box kit
CZ-P456HR3 4 ports 3 pipe box (up to 5,60kW)
CZ-P56HR3 Solenoid valve kit (up to 5,60kW)
CZ-CAPE2 3-Pipe control PCB
KIT-P160HR3 3-Pipe control Solenoid valve kit (from 5,6 to 10,60kW)
CZ-P160HR3 Solenoid valve kit (up to 16,00kW)
CZ-CAPE2 3-Pipe control PCB
CZ-P656HR3 6 ports 3 pipe box (up to 5,60kW) CZ-P856HR3 8 ports 3 pipe box (up to 5,60kW) CZ-P4160HR3 4 ports 3 pipe box (up to 16,00kW)
Solenoid valve kit
KIT-P56HR3 3-Pipe control Solenoid valve kit (up to 5,60kW)
PDF Data:
These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.