MODEL REPLACED BY SRF-ZS MODELS R32
Mitsubishi Heavy Industries Air Conditioning SRF25ZMX-S HYPER Inverter Floor Heat Pump 2.5 kW/9000Btu A++ 240V~50Hz
Constant temperature and uniform air distribution
MITSUBISHI HEAVY INDUSTRIES has made a giant leap forward in air conditioning and heat pump inverter technology, with the latest introduction of high performance SRF-ZMX Floor Mounted air conditioning systems. The NEW ADVANCED SRF Floor Mounted Indoor Units are a new design with a flat/low profile flat appearance, and is very easy to keep clean. The SRF includes the Mitsubishi innovative NATURAL ENZYME FILTER which destroys funghi, bacteria and viruses. This, combined with the main Photocatalytic Washable Deodorizing Filter, provides healthy clean air for the occupants. The recently introduced SRF slim indoor unit has a reduced depth of 293mm, the new multiple stage heat exchanger is folded to form a surround to the upper section of the fan enclosure. This ensures low air velocity, and reduced sound levels, whilst delivering high performance and efficiency. The unit produces an amazing 4.25 x input or 4250 watts for 1000 watt input.
Auto Air Outlet Selection:
In heating mode: Both lower and upper outlets operate with Auto fan speed
mode, the lower outlet will be kept for twenty minutes after the start or until room temperature is close to reaching the setting point. And then the air outlet will change to both outlets. That state will be maintained until the switch is turned off. Automatic adjustment of lower air outlet direction prevents stirring up of warm air and keeps optimum comfort at floor level.
In cooling mode: In case both lower and upper outlets operation is selected in
Cooling or Dry operation, both outlets will be kept for sixty minutes after the start or until room temperature is below the setting point. And then the air outlet will change to the upper outlet. That state will be maintained until switch is turned off. In case both outlets operation with Auto fan speed mode is selected, the upper outlet will be kept for ten minutes after the start or until room temperature is close to reaching the setting point. And then the air outlet will change to both outlets in order to spread comfort air to every corner.
Product Key Feature's:
• High CoP, up to 4.70
• New advanced technology control
• Infra-red controller with wall mounting bracket
• Reduced height slim construction
• Only 238mm deep
• Pipe runs up to 15 metres
• Low noise – 26dBA
• Back-up switch for loss of controller
• Cold draft prevention on heat pump
start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for
up to 15 metres pipe length
• Auto air direction with high and low air outlets for cooling/heating operations
Unit Data:
Indoor Unit Model
|
SRF 25 ZMX-S
|
Outdoor Unit Model
|
SRC 25 ZMX-S
|
Type
|
DC Inverter
|
Capacity (T=35°C)
|
Cooling
|
kW
|
2.50 (0.90~3.20)
|
Power Input (T=+35° C)
|
Cooling
|
kW
|
0.521 (0.19~0.82)
|
Annual Consumption
|
Cooling
|
kWh/a
|
127
|
Energy Efficiency Class Seasonal
|
Cooling
|
626/20111
|
A++
|
Energy Efficiency Class Seasonal Index
|
Cooling
|
SEER2
|
6.90
|
Energy Efficiency Rated
|
Cooling
|
EER3
|
4.80
|
Design load (Pdesignc)
|
Cooling
|
kW
|
2.50
|
Capacity (T=+7° C)
|
Heating
|
kW
|
3.40 (0.90~4.70)
|
Power Input (T=7° C)
|
Heating
|
kW
|
0.723 (0.23~1.20)
|
Annual Consumption
|
Heating
|
kWh/a
|
1053
|
Energy Efficiency Class Seasonal
|
Heating
|
626/20111
|
A+
|
Energy Efficiency Class Seasonal Index
|
Heating
|
SCOP2
|
4.12
|
Energy Efficiency Rated
|
Heating
|
COP3
|
4.70
|
Design load (Pdesignh) @-10°C
|
Heating
|
kW
|
3.10
|
T° operational limit (Tol)
|
Heating
|
°C
|
-15
|
Power supply
|
Ph-V-Hz
|
1-220~240V-50HZ
|
I.U. ~ O.U.
|
O.U.
|
Input Rated Current (Cooling - Heating)
|
A
|
2.6 - 3.6
|
Wiring cables i.u./o.u. (without ground)
|
nb.
|
3
|
Refrigerant Pipe Liquid/Gas side
|
mm (inch.)
|
6.35 (1/4”) - 9.52 (3/8”)
|
Max splitting distance I.U./O.U.
|
m
|
15
|
Max splitting level difference (O.U./I.U.-I.U./O.U.)
|
m
|
10/10
|
Refrigerant Precharge
|
Kg
|
1.20
|
MAX Splitting without Refrigerant Precharge
|
m
|
15
|
Refrigerant Precharge
|
g/m
|
-
|
Temperature range cooling
|
°C
|
-15°C~+46°C
|
Temperature range heating
|
°C
|
-15°C~+21°C
|
Indoor unit
|
Dimensions (HxWxD)
|
mm
|
600x860x238
|
Net weight
|
Kg
|
18
|
Indoor Noise level 1 m (Hi/Mi/Lo)
|
dB(A)
|
40
|
32
|
Power sound level
|
dB(A)
|
51
|
Indoor air flow (Hi/Mi/Lo)
|
m3/h
|
540
|
456
|
Drain hose diameter
|
mm
|
16
|
Remote control (st. equipment)
|
type
|
Infrared remote control
|
Filter (st. equipment)
|
1x
|
Natural enzyme filter
|
Filter (st. equipment)
|
1x
|
Photocatalytic
|
Outdoor Unit
|
Dimensions (HxWxD)
|
mm
|
590x780(+62)x290
|
Net weight
|
Kg
|
35
|
Max noise level 1 m
|
dB(A)
|
47
|
Power sound level
|
dB(A)
|
60
|
Max air flow
|
m3/h
|
1770
|
Interface for wired remote control &/or SC-ADNA-E (optional)
|
SC-BIKN-E
|
Wired remote control (optional)
|
RC-E5 / RC-EX1A
|
SUPERLINK II Interface (optional)
|
SC-ADNA-E
|
PDF Data:
These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.