Mitsubishi Heavy Industries Air Conditioning SRC60ZSX-W AHU-KIT-SP AHU Interface Connection 6Kw with RC-E5 Controller
This Kit Includes:
1 x Mitsubishi Heavy Industries Air Conditioning AHU INTERFACE AHU-KIT-SP 1 Phase 220- 240V, 50Hz
1 x Mitsubishi Heavy Industries Air Conditioning SRC60ZSX-W1 Outdoor Unit 6Kw R32 A++ 1 Phase 220- 240V, 50Hz
1 x Mitsubishi Heavy Industries Air Conditioning RC-E5 Wired Remote Controller 2 wire PAC
Mitsubishi Heavy Industries Air Conditioning has made a giant leap forward in air conditioning and heat pump technology, with the development of high performance R32 charged inverter series split outdoor systems ideally suited for commercial application such as offices, shops, meeting rooms, restaurants, hotels, clubs, gyms, and open plan areas. The heat exchangers have again been improved, now using slit-fins and inner grooved tubing for maximum efficiency in heating and cooling, whilst maintaining lower sound levels. The 7-Day Programmable timer is now included in the standard controls specification.
The AHU-KIT-SP is a specialized controller designed to seamlessly integrate any indoor Air Handling Unit (AHU) coil system with a Mitsubishi Heavy Industries Air Conditioning split-type outdoor unit. This cutting-edge interface offers a flexible and efficient solution for controlling the capacity of the connected outdoor unit.
Key Features:
-
Analog Input Control: Equipped with both 0–10V and 4–20mA analog inputs, the AHU interface provides a basic yet robust method for capacity control of the outdoor unit, ensuring precise and responsive adjustments to varying environmental needs.
-
Remote Controller Compatibility: In addition to the analog control methods, this interface kit allows for setting temperature adjustments through a remote controller. This feature adds an extra layer of convenience and user-friendliness, making it easier to manage the system from different locations.
-
Modbus Protocol Communication: A standout feature of the AHU-KIT-SP is its ability to communicate using the Modbus protocol. This functionality enables detailed capacity control (ranging from 0–100%) and temperature setting adjustments to be made as per specific requirements, offering unparalleled flexibility and precision in system management.
-
Comprehensive Integration: Designed specifically for use with Mitsubishi Heavy Industries Air Conditioning systems, the AHU interface ensures a seamless and efficient integration, enhancing the overall performance and reliability of your HVAC system.
-
Versatile Application: Whether it's for basic capacity control or more advanced temperature setting adjustments, the AHU-KIT-SP is equipped to handle a wide range of indoor environmental conditions, making it a versatile choice for various indoor spaces.
Key Product Features:
7-Day Programmable Timer
• Two on/off settings each day
• Different temperature for each set period
• External timer/8MS switching for Group (up to 16 units)
• Wall Controller - hard wired
• Integral temperature sensor
• Low ambient control included
• Auto re-start after power interruption
Technical Specification:
OUTDOOR UNIT |
|
SRC60ZSX-W |
AHU INTERFACE |
|
AHU-KIT-SP2 |
CONTROLLER |
|
RC-E5 |
Nominal Cooling Capacity (Min-Max) |
kW |
5.6 (1.1 - 6.3) |
Nominal Heating Capacity (Min-Max) |
kW |
6.7 (0.6 - 6.7) |
Coil Air Flow |
m3/hr |
min 480 |
Air On Temperature Cooling (Min/Max) |
|
16° / 32°C |
Air On Temperature Heating (Min/Max) |
|
10° / 32°C |
Max. Pipe Run |
m |
30 |
Pipe Sizes |
in |
1/4" - 1/2" |
Replacement Technology |
|
Yes |
Outdoor Power Supply (V-Ph-Hz) |
|
230 - 1 - 50 |
UK Cooling Capacity |
kW |
5.3 |
UK Heating Capacity |
kW |
5 |
Recommended AHU Coil/Circuit Volume |
cm3 |
≤ 1680 |
Recommended Airfl w Volume |
m3/s |
0.300 |
PDF Data:
These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.