High Seasonal Efficiency A++ Rated
Includes:
1 x Mitsubishi Heavy Industries Air Conditioning SCM40ZS-W R32 Multi 2 Port A++ 240V~50Hz
2 x SCM25ZSP-S Wall Mounted Indoor Units 2.5KW
2 x Ir Controllers
SCM Series Outdoor Unit
The Mitsubishi Heavy Industries air conditioning SCM variable capacity multi-room systems are ideal for light commercial and residential applications and offer the user the high CoP up to 4.02 and low start up currents making them ideal where there is limited power supply. The SCM Inverter outdoor units are suitable for 2, 3, or 4 connected indoor units, depending on the model. Each indoor unit is connected directly by a pair of small diameter refrigerant pipes to the outdoor unit. There are no branch joints involved and all connected indoor units operate in the same mode, i.e. either all Heating, or all Cooling.
ZSP Indoor Unit Series
The new slim profile indoor unit has a reduced height of 275mm, allowing installation above door openings and windows. The new multiple stage heat exchanger is folded to form a surround to the upper section of the fan enclosure. This ensures low air velocity, and reduced sound levels, whilst delivering high performance and efficiency.
Product Key Feature's:
• High CoP, up to record 4.03
• 1 Outdoor unit saving space
• Energy saving inverter
• New advanced technology control
• Infra-red controller with wall mounting bracket
• Reduced height slim construction
• Pipe runs up to 30 metres
• Low noise – 22dBA on smaller models
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for
up to 30 metres pipe length
Indoor Wall Mounted Technical Specification:
Indoor unit
|
|
SCM25ZSP-W
|
Power source
|
|
1 Phase, 220 - 240V, 50Hz
|
Nominal cooling capacity (Min~Max)
|
kW
|
2.5(0.9~2.8)
|
Nominal heating capacity (Min~Max)
|
kW
|
2.8(0.8~3.9)
|
EER/COP
|
Cooling/Heating
|
|
3.21/3.71
|
*Sound power level
|
Indoor
|
Cooling/Heating
|
dB(A)
|
58/ 57
|
*Sound pressure level
|
Indoor
|
Cooling (Hi/Me/Lo)
|
43/ 34 / 23
|
Heating (Hi/Me/Lo)
|
43 / 34 / 26
|
Air flow
|
Indoor
|
Cooling (Hi/Me/Lo)
|
m3/min
|
10.1 / 7.3 / 4.2
|
Heating (Hi/Me/Lo)
|
9.5 / 7.3 / 5.2
|
Exterior dimensions
|
Indoor
|
Height x Width x Depth
|
mm
|
267 x 783 x 210
|
|
Net weight
|
Indoor
|
kg
|
7
|
Ref.piping size
|
Liquid/Gas
|
ø mm
|
6.35(1/4") / 9.52(3/8")
|
Clean filter
|
|
- YES
|
Outdoor Technical Specification:
|
Outdoor Unit
|
|
SCM40ZS-W
|
EFFICIENCY
|
Nominal Cooling (Min-Max)
|
kW
|
4 (1.5-5.9)
|
Nominal Heating (Min-Max)
|
kW
|
4.5 (1.3-6.3)
|
Number of Connectable Indoors
|
|
Min 2 Max 2
|
EER - COP (Cool - Heat)
|
|
4.76 - 5
|
Energy Label (Cool / Heat)
|
|
A / A
|
CONDITIONS
|
Operating Range (Cooling)
|
°C
|
43 to -15
|
Operating Range (Heating)
|
°C
|
24 to -15
|
DIMENSIONS & WEIGHT
|
Indoor Unit Dim. (H-W-D)
|
mm
|
595 -780 (+90)
- 290
|
Outdoor Weight
|
kg
|
42
|
NOISE LEVELS &
|
Sound Pressure Level (Cool-Heat)
|
dB(A)
|
48 - 50
|
Airflow Rate Cool – Heat
|
m3/min
|
32.5 - 32.5
|
Max External Static Pressure
|
Pa
|
0
|
REFRIGERANT & PIPEWORK
|
Pipe Sizes (Gas - Liquid)
|
in
|
3/8” - 1/4” x 2
|
Maximum Pipe Run (Per Unit)
|
m
|
25
|
Maximum Pipe Run (Total)
|
m
|
30
|
Maximum Height Difference
|
m
|
15
|
Pre-Charged for
|
m
|
30
|
Factory Charge
|
kg
|
1.9
|
Additional Charge
|
g/m
|
20g/m
|
Suitable For Replacement Tech.
|
|
No
|
ELECTRICAL DATA
|
Power Supply (Outdoor)
|
V-Ph-Hz
|
230 - 1 - 50
|
Suggested Fuse Size
|
A
|
25
|
Power Input Cool - Heat
|
kW
|
0.84 - 0.9
|
Running Current Cool - Heat
|
A
|
4 - 4.2
|
Start - Max Run Current
|
A
|
4.2
|
Interconnecting Cables
|
|
3 core + E
|
Combination Chart Output:
Indoor Unit Combination
|
Cooling Capacity (kW)
|
Power Consumption (W)
|
Standard Current (A)
|
Room Cooling Capacity
|
Total Capacity
|
Min.
|
Standard
|
Max.
|
220V
|
230V
|
240V
|
A
|
B
|
Min.
|
Standard
|
Max.
|
Cooling Operation
|
1
room
|
20
|
2.0
|
-
|
1.5
|
2.0
|
2.7
|
560
|
650
|
880
|
3.2
|
3.1
|
3.0
|
25
|
2.5
|
-
|
1.5
|
2.5
|
3.2
|
560
|
830
|
1040
|
4.1
|
4.0
|
3.8
|
35
|
3.5
|
-
|
1.5
|
3.5
|
3.7
|
560
|
1100
|
1200
|
5.5
|
5.2
|
5.0
|
2
room
|
20 + 20
|
2.00
|
2.00
|
3.0
|
4.0
|
5.6
|
600
|
1050
|
1750
|
5.2
|
5.0
|
4.8
|
20 + 25
|
2.00
|
2.50
|
3.0
|
4.5
|
5.8
|
600
|
1300
|
2030
|
6.3
|
6.0
|
5.8
|
20 + 35
|
1.89
|
3.31
|
3.0
|
5.2
|
5.8
|
600
|
1600
|
2030
|
7.5
|
7.2
|
6.9
|
25 + 25
|
2.50
|
2.50
|
3.0
|
5.0
|
5.8
|
600
|
1420
|
2030
|
6.7
|
6.4
|
6.2
|
25 + 35
|
2.17
|
3.03
|
3.0
|
5.2
|
5.8
|
600
|
1600
|
2030
|
7.5
|
7.2
|
6.9
|
PDF Data Sheet:

These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.