Mitsubishi Heavy Industries Air Conditioning SCM40ZS-W Multi 2 x SRK20ZS R32 240V~50Hz

High Seasonal Efficiency A+ Rated    


 


Includes: 


1 x Mitsubishi Heavy Industries Air Conditioning SCM40ZS-W Multi 2 Port R32 4Kw / 14000Btu A+ 240V~50Hz

1 x Mitsubishi Heavy Industries Air Conditioning SRK20ZS-W 2Kw R32 240V~50Hz

2 x Ir Remote Controllers





 

SCM Series Outdoor Unit:


The Mitsubishi Heavy Industries air conditioning SCM variable capacity multi-room systems are ideal for light commercial and residential applications and offer the user the high sCoP and low start up currents making them ideal where there is limited single phase power supply. The SCM Inverter outdoor units are suitable for 2, 3, 4 or 5 connected indoor units, depending on the model. Each indoor unit is connected directly by a pair of small diameter refrigerant pipes to the outdoor unit. There are no branch joints involved and all connected indoor units operate in the same mode, i.e. either all Heating, or all Cooling. 


 




ZS Series Indoor Unit:


The new slim profile indoor unit has a reduced height of 290mm, allowing installation above door openings and windows. The new multiple stage heat exchanger is folded to form a surround to the upper section of the fan enclosure. This ensures low air velocity, and reduced sound levels, whilst delivering high performance and efficiency. The new generation of SRK- indoor units is now even more user friendly with an optional Wi-Fi gateway device installed inside the unit makes it possible for the unit to be controlled via smart phone, tablet. This is smart air conditioning, evolving around your schedule. Whether you are on the go, away or at home – the control of your air conditioner is only one fingertip away.


 



Product Key Feature's:





• High CoP, up to record 
• 1 Outdoor unit saving space
• Energy saving inverter
• New advanced technology control
• Infra-red controller with wall mounting bracket
• Reduced height slim construction
• Long pipe runs 
• Low noise – 22dBA on smaller models
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 30 metres pipe length




Indoor Wall Mounted Technical Specification:

 

   
Nominal cooling capacity (min-max) kW 2.0 (1.0 - 2.8)
Nominal heating capacity (min-max) kW 2.7 (0.9 - 4.2)
Exterior Dimensions (H x W x D) mm 290 x 870 x 230
Net Weight kg 9.5
Air Flow Cooling (Hi/Me/Lo) m3/min 9.3 / 7.0 / 5.9 / 5.0
Air Flow Heating (Hi/Me/Lo) m3/min 10.0 / 8.5 / 6.5 / 5.9
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 34 / 25 /22 / 19
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 36 / 29 / 23 / 19

 

Electrical Data:

Pdesignc kW 2
Pdesignh (@-10°C) kW 2.40
Annual electricity consumption (Cooling/Heating) kWh/a 90 / 732
Power Source 1Phase, 220 - 240V, 50Hz
Inrush current (220/230/240v) A 3.2 / 3.1 / 3.0
Max. running current A 9
Power consumption (Cooling/Heating) kW 0.44 / 0.62



Installation:

 
Refrigerant (GWP) R32 
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4") / 9.52 (3/8")
Ref. Max Piping Length m Max. 20
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10


 




Outdoor Technical Specification:

Outdoor Unit

SCM40ZS-S

EFFICIENCY

Nominal Cooling (Min-Max)

kW

4 (1.5-5.9)

Nominal Heating (Min-Max)

kW

4.5 (1.3-6.3)

Number of Connectable Indoors

Min 2 Max 2

EER - COP (Cool - Heat)

4.76 - 5

Energy Label (Cool / Heat)

A / A

CONDI- TIONS

Operating Range (Cooling)

°C

43 to -15

Operating Range (Heating)

°C

24 to -15

DIMEN- SIONS & WEIGHT

Indoor Unit Dim. (H-W-D)

mm

595 -780 (+90)

- 290

Outdoor Weight

kg

42

NOISE LEVELS &

Sound Pressure Level (Cool-Heat)

dB(A)

48 - 50

Airflow Rate Cool – Heat

m3/min

32.5 - 32.5

Max External Static Pressure

Pa

0

REFRIGERANT & PIPEWORK

Pipe Sizes (Gas - Liquid)

in

3/8” - 1/4” x 2

Maximum Pipe Run (Per Unit)

m

25

Maximum Pipe Run (Total)

m

30

Maximum Height Difference

m

15

Pre-Charged for

m

30

Factory Charge

kg

1.9

Additional Charge

g/m

20g/m

Suitable For Replacement Tech.

No

ELECTRICAL DATA

Power Supply (Outdoor)

V-Ph-Hz

230 - 1 - 50

Suggested Fuse Size

A

25

Power Input Cool - Heat

kW

0.84 - 0.9

Running Current Cool - Heat

A

4 - 4.2

Start - Max Run Current

A

4.2

Interconnecting Cables

3 core + E


 


Combination Chart Output / Unit:




 

Indoor Unit Combination

Cooling Capacity (kW)

Power Consumption (W)

Standard Current (A)

Room Cooling Capacity

Total Capacity

Min.

Standard

Max.

220V

230V

240V

A

B

Min.

Standard

Max.

Cooling Operation

1

room

20

2.0

-

1.5

2.0

2.7

560

650

880

3.2

3.1

3.0

25

2.5

-

1.5

2.5

3.2

560

830

1040

4.1

4.0

3.8

35

3.5

-

1.5

3.5

3.7

560

1100

1200

5.5

5.2

5.0

2

room

20  +  20

2.00

2.00

3.0

4.0

5.6

600

1050

1750

5.2

5.0

4.8

20  +  25

2.00

2.50

3.0

4.5

5.8

600

1300

2030

6.3

6.0

5.8

20  +  35

1.89

3.31

3.0

5.2

5.8

600

1600

2030

7.5

7.2

6.9

25  +  25

2.50

2.50

3.0

5.0

5.8

600

1420

2030

6.7

6.4

6.2

25  +  35

2.17

3.03

3.0

5.2

5.8

600

1600

2030

7.5

7.2

6.9



 

PDF Data Sheet:
 


http://www.orionairsales.co.uk/ekmps/shops/orionair/resources/Design/pdf-download-image.jpg
 




These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.