High Seasonal Efficiency A Rated
Includes:
1 x SCM40ZM-S Condensing unit
1 x SRK25ZS Wall Mounted Indoor units 2.5KW
1 x SRK20ZS Wall Mounted Indoor units 2.0KW
2 x Controllers

SCM Series Outdoor Unit:
The Mitsubishi Heavy Industries air conditioning SCM variable capacity multi room systems are ideal for light commercial and residential applications and offer the user the high CoP up to 4.02 and low start up currents making them ideal where there is limited power supply. The SCM Inverter outdoor units are suitable for 2, 3, or 4 connected indoor units, depending on the model. Each indoor unit is connected directly by a pair of small diameter refrigerant pipes to the outdoor unit. There are no branch joints involved and all connected indoor units operate in the same mode, i.e. either all Heating, or all Cooling.
ZS Series Indoor Unit:
The new slim profile indoor unit has a reduced height of 290mm, allowing installation above door openings and windows. The new multiple stage heat exchanger is folded to form a surround to the upper section of the fan enclosure. This ensures low air velocity, and reduced sound levels, whilst delivering high performance and efficiency. The new generation of SRK- indoor units is now even more user friendly with an optional Wi-Fi gateway device installed inside the unit makes it possible for the unit to be controlled via smart phone, tablet. This is smart air conditioning, evolving around your schedule. Whether you are on the go, away or at home – the control of your air conditioner is only one fingertip away!
Product Key Feature's:
• High CoP, up to record 4.03
• 1 Outdoor unit saving space
• Energy saving inverter
• New advanced technology control
• Infra-red controller with wall mounting bracket
• Reduced height slim construction
• Pipe runs up to 30 metres
• Low noise – 22dBA on smaller models
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for
up to 30 metres pipe length
Indoor Wall Mounted Technical Specification:
Indoor unit
|
|
SRK25ZS-S,-SB,-ST
|
Outdoor unit
|
|
SRC25ZS-S
|
Power source
|
|
1 Phase, 220 - 240V, 50Hz
|
Nominal cooling capacity (Min~Max)
|
kW
|
2.5(1.0~3.0)
|
Nominal heating capacity (Min~Max)
|
kW
|
3.2(0.9~4.4)
|
Power consumption
|
Cooling/Heating
|
kW
|
0.62 / 0.80
|
EER/COP
|
Cooling/Heating
|
|
4.03 / 4.00
|
Max. running current
|
|
A
|
9
|
Sound power level
|
Indoor
|
Cooling/Heating
|
dB(A)
|
52 / 55
|
Outdoor
|
Cooling/Heating
|
58 / 58
|
Sound pressure level
|
Indoor
|
Cooling (Hi/Me/Lo/Ulo)
|
36 / 28 / 23 / 19
|
Heating (Hi/Me/Lo/Ulo)
|
39 / 30 / 24 / 19
|
Outdoor
|
Cooling/Heating
|
46 / 46
|
Air flow
|
Indoor
|
Cooling (Hi/Me/Lo/Ulo)
|
m3/min
|
9.9 / 8.0 / 5.9 / 5.0
|
Heating (Hi/Me/Lo/Ulo)
|
11.3 / 8.7 / 6.7 / 5.9
|
Outdoor
|
Cooling/Heating
|
27.4 / 23.6
|
Exterior dimensions
|
Indoor
|
HeightxWidthxDepth
|
mm
|
290 x 870 x 230
|
Outdoor
|
540 x 780(+62) x 290
|
Net weight
|
Indoor / Outdoor
|
kg
|
9.5 / 31.5
|
Refrigerant
|
Type/GWP
|
|
R410A / 2088
|
Charge
|
kg/TCO2Eq
|
0.75 / 1.566
|
Refrigerant piping size
|
Liquid/Gas
|
ø mm
|
6.35(1/4") / 9.52(3/8")
|
Refrigerant line (one way) length
|
m
|
Max. 20
|
Vertical height differences
|
Outdoor is higher/lower
|
m
|
Max. 10 / Max. 10
|
Outdoor operating temperature range
|
Cooling
|
˚C
|
-15~46
|
Heating
|
-15~24
|
Clean filter
|
|
|
Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
|
Nominal cooling capacity (min-max) |
kW |
2.0 (1.0 - 2.8) |
Nominal heating capacity (min-max) |
kW |
2.7 (0.9 - 4.2) |
Exterior Dimensions (H x W x D) |
mm |
290 x 870 x 230 |
Net Weight |
kg |
9.5 |
Air Flow Cooling (Hi/Me/Lo) |
m3/min |
9.3 / 7.0 / 5.9 / 5.0 |
Air Flow Heating (Hi/Me/Lo) |
m3/min |
10.0 / 8.5 / 6.5 / 5.9 |
Sound Pressure Level Cooling (Hi/Me/Lo) |
dB(A) |
34 / 25 /22 / 19 |
Sound Pressure Level Heating (Hi/Me/Lo) |
dB(A) |
36 / 29 / 23 / 19 |
・The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating: Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
・Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
・‘tonne(s) of CO2 equivalent’ means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
Outdoor Technical Specification:
|
Outdoor Unit
|
|
SCM40ZS-S
|
EFFICIENCY
|
Nominal Cooling (Min-Max)
|
kW
|
4 (1.5-5.9)
|
Nominal Heating (Min-Max)
|
kW
|
4.5 (1.3-6.3)
|
Number of Connectable Indoors
|
|
Min 2 Max 2
|
EER - COP (Cool - Heat)
|
|
4.76 - 5
|
Energy Label (Cool / Heat)
|
|
A / A
|
CONDI- TIONS
|
Operating Range (Cooling)
|
°C
|
43 to -15
|
Operating Range (Heating)
|
°C
|
24 to -15
|
DIMEN- SIONS & WEIGHT
|
Indoor Unit Dim. (H-W-D)
|
mm
|
595 -780 (+90)
- 290
|
Outdoor Weight
|
kg
|
42
|
NOISE LEVELS &
|
Sound Pressure Level (Cool-Heat)
|
dB(A)
|
48 - 50
|
Airflow Rate Cool – Heat
|
m3/min
|
32.5 - 32.5
|
Max External Static Pressure
|
Pa
|
0
|
REFRIGERANT & PIPEWORK
|
Pipe Sizes (Gas - Liquid)
|
in
|
3/8” - 1/4” x 2
|
Maximum Pipe Run (Per Unit)
|
m
|
25
|
Maximum Pipe Run (Total)
|
m
|
30
|
Maximum Height Difference
|
m
|
15
|
Pre-Charged for
|
m
|
30
|
Factory Charge
|
kg
|
1.9
|
Additional Charge
|
g/m
|
20g/m
|
Suitable For Replacement Tech.
|
|
No
|
ELECTRICAL DATA
|
Power Supply (Outdoor)
|
V-Ph-Hz
|
230 - 1 - 50
|
Suggested Fuse Size
|
A
|
25
|
Power Input Cool - Heat
|
kW
|
0.84 - 0.9
|
Running Current Cool - Heat
|
A
|
4 - 4.2
|
Start - Max Run Current
|
A
|
4.2
|
Interconnecting Cables
|
|
3 core + E
|
Combination Chart Output:
Indoor Unit Combination
|
Cooling Capacity (kW)
|
Power Consumption (W)
|
Standard Current (A)
|
Room Cooling Capacity
|
Total Capacity
|
Min.
|
Standard
|
Max.
|
220V
|
230V
|
240V
|
A
|
B
|
Min.
|
Standard
|
Max.
|
Cooling Operation
|
1
room
|
20
|
2.0
|
-
|
1.5
|
2.0
|
2.7
|
560
|
650
|
880
|
3.2
|
3.1
|
3.0
|
25
|
2.5
|
-
|
1.5
|
2.5
|
3.2
|
560
|
830
|
1040
|
4.1
|
4.0
|
3.8
|
35
|
3.5
|
-
|
1.5
|
3.5
|
3.7
|
560
|
1100
|
1200
|
5.5
|
5.2
|
5.0
|
2
room
|
20 + 20
|
2.00
|
2.00
|
3.0
|
4.0
|
5.6
|
600
|
1050
|
1750
|
5.2
|
5.0
|
4.8
|
20 + 25
|
2.00
|
2.50
|
3.0
|
4.5
|
5.8
|
600
|
1300
|
2030
|
6.3
|
6.0
|
5.8
|
20 + 35
|
1.89
|
3.31
|
3.0
|
5.2
|
5.8
|
600
|
1600
|
2030
|
7.5
|
7.2
|
6.9
|
25 + 25
|
2.50
|
2.50
|
3.0
|
5.0
|
5.8
|
600
|
1420
|
2030
|
6.7
|
6.4
|
6.2
|
25 + 35
|
2.17
|
3.03
|
3.0
|
5.2
|
5.8
|
600
|
1600
|
2030
|
7.5
|
7.2
|
6.9
|
PDF Data Sheet:

These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.