Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Mitsubishi Heavy Industries FDUM Ducted Air Conditioning Inverter Heat Pump

Mitsubishi Heavy Industries Air Conditioning FDUM140VH Ducted Ceiling Concealed 14Kw/48000Btu R32 A

  • Mitsubishi Heavy Industries Air Conditioning FDUM140VH Ducted Ceiling Concealed 14Kw/48000Btu R32 A
  • Mitsubishi Heavy Industries Air Conditioning FDUM140VH Ducted Ceiling Concealed 14Kw/48000Btu R32 A
  • Mitsubishi Heavy Industries Air Conditioning FDUM140VH Ducted Ceiling Concealed 14Kw/48000Btu R32 A
  • Mitsubishi Heavy Industries Air Conditioning FDUM140VH Ducted Ceiling Concealed 14Kw/48000Btu R32 A
  • Mitsubishi Heavy Industries Air Conditioning FDUM140VH Ducted Ceiling Concealed 14Kw/48000Btu R32 A

Mitsubishi Heavy Industries Air Conditioning FDUM140VH Ducted Ceiling Concealed 14Kw/48000Btu R32 A

£2,850.75 £2,375.63 (ex. VAT)
Stock Status: In Stock

Mitsubishi Heavy Industries Air Conditioning FDC140ZN/SX-W FDUM140VH Ducted Ceiling Concealed 14Kw/48000Btu R32 A 240V/415~50Hz

This Kit Includes:


 

1 x Mitsubishi Heavy Industries Air Conditioning FDUM140VH Ducted Ceiling Concealed R32 14Kw/48000Btu A+

1 x Mitsubishi Heavy Industries Air Conditioning FDC140VN/SX-W 14Kw/48000Btu A+ R32 Outdoor Unit (SELECT VOLTAGE)

1 x Mitsubishi Heavy Industries Air Conditioning Eco Touch RC-EX3A Wired Remote Controller 2 wire PAC 

1 x Mitsubishi Heavy Industries Air Conditioning UM-FL1/2/3EF Return Air Filter


Ducted Heat Pumps for Commercial & Residential Applications. Ideal for concealed cooling, multiple area applications or irregular shaped rooms. FDUM Ducted units are of robust construction, and are fitted with large diameter fans for optimum air volume, whilst maintaining low sound levels. Condensate Pump included. Return plenums with filters available as a option for easy installation. Plenum outlets and inlets 200mm. Duct design was simplified. Using DC motor, the most optimum air flow volume can be achieved by this automatic control. Indoor unit will recognise external static pressure by itself automatically and keep rated air flow volume.




Superior Controls Specification: There has never been a multi function controller with the advanced sophistication of the new Mitsubishi RC-EX1A. It combines all the basic user requirements - temperature setting, fan speed selection, mode, and timer settings, with a comprehensive range of service data functions, inverter compressor speed indication, fault diagnosis, and operational history.


FDUM Key Product Features:



7-Day Programmable Timer
• Two on/off settings each day
• Different temperature for each set period
• External timer/8MS switching for Group (up to 16 units)
• Wall Controller - hard wired
• Integral temperature sensor
• Condensate Lift Pump included
• Low ambient control included
• Auto re-start after power interruption
• Compatible with Multi Systems



 

FDUM Technical Specification:

Indoor unit

FDUM140VH

Outdoor unit

FDC140VN/SX-W

Power source

VNX: 1 Phase 220-240V, 50Hz

VNS: 3 Phase 380-415V, 50Hz / 380V, 60Hz

Nominal cooling capacity (Min~Max)

kW

14.0 ( 3.5 ~ 16.0 )

Nominal heating capacity (Min~Max)

kW

16.0 ( 2.7 ~ 20.0 )

Power consumption

Cooling/Heating

kW

4.22 / 4.22

EER/COP

Cooling/Heating

3.32 / 3.79

Inrush current

A

5

Max. running current

A

17

Sound power level*1

Indoor *3

Cooling/Heating

dB(A)

70 / 70

Outdoor

Cooling/Heating

69 / 71

Sound pressure level*1

Indoor *3

Cooling (Hi/Me/Lo/Ulo)

47 / 40 / 35 / 30

Heating (Hi/Me/Lo/Ulo)

47 / 40 / 35 / 30

Outdoor

Cooling/Heating

54 / 54

Air flow

Indoor *3

Cooling (Hi/Me/Lo/Ulo)

m3/min

48 / 35 / 28 / 22

Heating (Hi/Me/Lo/Ulo)

48 / 35 / 28 / 22

Outdoor

Cooling/Heating

100 / 100

Available external static pressure

Pa

Standard:60 Max:100

Exterior Dimensions

Indoor

Height x Width x Depth

mm

280 x 1,370 x 740

Outdoor

1,300 x 970 x 370

Net weight

Indoor / Outdoor

kg

54 / 99

Refrigerant

Type/GWP

R32/675

Refrigerant piping size

Liquid/Gas

ø mm

9.52(3/8") / 15.88(5/8")

Refrigerant line (one way) length

m

Max.100

Vertical height differences

Outdoor is higher/lower

m

Max.50 / Max.15

Outdoor operating temperature range

Cooling*2

°C

-15~50

Heating

-20~20

Air filter quantity

(Option) Filter kit : UM-FL3EF

Remote control (option)

wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-KIT4-E2

SEER

5.79

SCOP (Average climate)

3.88

PDF Data:



 


These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.