A++ Energy rated product
This kit includes:
1 x Mitsubishi Electric Air Conditioning Cassette PLA-ZM100EA Heat Pump 10Kw/34000Btu R32
1 x Mitsubishi Electric Air Conditioning PUZ-ZM100VKAR1 Power Inverter Heat Pump 10Kw/34000Btu R32 A++ 240V~50Hz
1 x Mitsubishi Electric Air Conditioning fascia panel
1 x Wired remote control PAR40MAA

The new square grille design of the PLA-ZM beautifully harmonises with any interior, making it ideal for applications such as offices or retail stores. New horizontal airflow control helps remove uncomfortable draughts and improve comfort levels. The PLA Cassette Heat Pumps for Commercial And Residential Applications. Ideal for large open plan areas, or irregular shaped rooms.
The renowned Mitsubishi Electric air conditioning Mr Slim power inverter PLA-ZM cassette range has now been extended to include new small capacity R32 system's starting at 3.5kW / 12000Btu, and a high capacity system 14kW at the top end. (figures stated are for cooling/heating performance). The advanced 7-Day Programmable Timer is now included as standard controls specification and 24Hr control. Mitsubishi Electric air conditioning and heat pump high performance power inverter cassette series split systems designed for residential and commercial application such as offices, shops, meeting rooms, restaurants, hotels, clubs, gyms, and open plan areas. The units have a extended pipe run capability of up to 100 meters making them ideal for high-rise buildings.
The Mitsubishi Electric air conditioning Mr Slim power inverter air conditioning system's sCoP (Coefficient of Performance) is up to 4.9 on some models. This means the system can deliver 4.9 kW of heating, whilst consuming only 1.0kW of electrical power. This has been achieved by combining advanced Mitsubishi Electric air conditioning inverter technology with R32 refrigerant. The cassette design has improved air flow-pattern through the unit, and the new design of the high performance indoor heat exchanger, have resulted in a pressure loss reduction, allowing the fan design to be optimised for significantly lower sound Db levels. The air discharge louver has been modified to minimise air smudging on the ceiling adjacent to the air outlets.
Quiet Operation
The indoor unit has a quiet operational noise of 27dB in quiet mode to offer you peace and quiet for the bedroom or office. In addition, the outdoor units have drastically reduced vibration and noise thanks to a super quiet fan and motor and an innovative anti noise mechanism.
Heating / cooling and dehumidification
This unit heats, cools and dehumidifies.
Healthy De humidification
Dehumidification mode reduces uncomfortable humidity from the room without over cooling.
Auto Changeover
The air conditioner will switch automatically from cooling to heating modes depending on the set temperature.
Optimized Cooling & Heating Air Flow
The air vanes will be adjusted according to the mode of operation. In heating mode air will be distributed at a lower angle due to hot air rising.
Swirl Swing
Swirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the louvers.
Space Control:
The vane angle can be set in two positions to give optimum indoor comfort. It can be controlled by wired remote control to eliminate direct drafts which can lead to discomfort and reduced productivity.
Product Key Feature's:
• Anti Corrosion Fin (Outdoor)
• Weekly Program
• High Head Drain Pump
• Auto Changeover
• Low Standby Power
• Auto Restart
• Central Controller
• Easy-to-Clean Air Filter
• Two Thermistor Control
• Optimal Air Distribution with side knock outs
• Quiet Operation
• Healthy Dehumidification
• Hot Start
• 24-Hour ON/OFF Setting Timer
• Optimal air distribution with 4-way directional Air flow system.
• 4-way Auto Swing
• R32 Refrigerant
Technical Information:
PLA-ZM - INDOOR UNITS
|
PLA-ZM100EA
|
CAPACITY (kW) Heating (nominal) |
11.2 (4.5-14.0)
|
Cooling (nominal)
|
9.5 (4.9-11.4)
|
Heating (UK)
|
9.5 (3.85-11.9)
|
Cooling (UK)
|
9.2 (4.5-10.5)
|
SHF (nominal)
|
0.77
|
COP / EER (nominal)
|
4.30 / 4.60
|
SCOP / SEER (BS EN14825)
|
4.80 / 7.70
|
ERP ENERGY EFFICIENCY CLASS Heating/Cooling
|
A++ / A++
|
(l/s) Lo-Mi-Mi2-Hi |
317-367-417-467
|
SIZE MM (in) Gas/Liquid |
15.88 (5/8”) / 9.52 (3/8”)
|
PRESSURE LEVEL (dBA) Lo-Mi-Mi2-Hi |
31-34-37-40
|
SOUND POWER LEVEL (dBA)
|
61
|
Dimensions (mm) Width x Depth x Height (Grille) |
840 (950) x 840 (950) x 298 (40)
|
Weight (kg) Unit / Grille |
26 / 5
|
ELECTRICAL SUPPLY
|
Fed by Outdoor Unit
|
FUSE RATING (BS88) - HRC (A)
|
6
|
INTERCONNECTING CABLE NO. CORES
|
4
|
GRILLE REFERENCE
|
PLP-6EA
|
WIRED REMOTE CONTROLLER REFERENCE
|
PAR-33MAA
|
WIRELESS REMOTE CONTROLLER REFERENCE
|
PAR-SL100A-E
|
PUZ-ZM - OUTDOOR UNITS
|
|
PUZ-ZM100VKA 1 phase
|
PUZ-ZM100YKA 3 three phase
|
SOUND PRESSURE LEVEL (dBA)
|
Heating/Cooling
|
51 / 49
|
51 / 49
|
SOUND POWER LEVEL (dBA)
|
Cooling
|
69
|
69
|
WEIGHT (kg)
|
|
116
|
123
|
DIMENSIONS (mm)
|
Width x Depth x Height
|
1050 x 330 + 40 x 1338
|
1050 x 330 + 40 x 1338
|
ELECTRICAL SUPPLY
|
|
220-240v, 50Hz
|
380-415v, 50Hz
|
PHASE
|
|
Single
|
Three
|
SYSTEM POWER INPUT (kW)
|
Heating/Cooling (nominal)
|
2.604 / 2.065
|
2.604 / 2.065
|
|
Heating/Cooling (UK)
|
2.09 / 1.77
|
2.09 / 1.77
|
STARTING CURRENT (A)
|
|
13.0
|
6.0
|
SYSTEM RUNNING CURRENT (A)
|
Heating/Cooling [MAX]
|
11.25 / 8.97 [27.0]
|
3.75 / 2.96 [8.5]
|
FUSE RATING (BS88) - HRC (A)
|
|
32
|
16
|
MAINS CABLE NO. CORES
|
|
3
|
5
|
MAX PIPE LENGTH (m)
|
|
100
|
100
|
MAX HEIGHT DIFFERENCE (m)
|
|
30
|
30
|
CHARGE REFRIGERANT (kg) / CO2 EQUIVALENT (t)
|
R32 (GWP 675) - 30m
|
4.00 / 2.70
|
4.00 / 2.70
|
MAX ADDITIONAL REFRIGERANT (kg) / CO2 EQUIVALENT
|
R32 (GWP 675)
|
2.80 / 1.89
|
2.80 / 1.89
|
PDF Data:

These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.