Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Lg Air Conditioning Multi Systems A++

Lg Air Conditioning MU2R15-UL0 Multi Room Heat Pump Inverter 2 Port 4Kw/14000Btu A+++ R32 240V~50Hz

Lg Air Conditioning MU2R15-UL0 Multi Room Heat Pump Inverter 2 Port 4Kw/14000Btu A+++ R32 240V~50Hz

£1,123.88 £936.57 (ex. VAT)
Stock Status: In Stock
Blog

 
Lg Air Conditioning MU2R15-UL0 Multi Room Heat Pump Inverter 2 Port 4Kw/14000Btu A+++ R32 220-240V~50Hz






Includes:

1 x Lg Air Conditioning Multi Room Heat Pump Inverter 2 Port 4Kw/14000Btu A+++ R32 220-240V~50Hz



About Lg's Multi Inverter Air Conditioning Unit:

The Lg multi split air conditioning inverter heat pump units make it possible to have multiple combinations of different indoor units with different capacities with the advantage of a space saving outdoor condensing unit. The latest Lg Inverter heat pump technology allows greater performance, lower sound levels, lower energy consumption and operates at optimum performance in a rapid and uniform manner until the temperature reaches its optimum set point. The DC Inverter multi split heat pump outdoor units are more efficient than their predecessor and Lg air conditioning's renowned inverter technology is an innovative, energy-efficient feature that automatically adjusts the unit’s power to maintain room temperature across all the indoor units connected, rather than repeatedly starting and stopping the compressor. The patented Gold Fin™ process on the outdoor condensing unit is standard on the LG multi outdoor units and is an anti-corrosion coating that forms a protective shield against the elements to increase the product lifetime. As there is no need to install a large number of outdoor units, the outside aesthetics of the building are virtually unaffected, furthermore, the outdoor units offer great location flexibility to ease the installation.



 



Technical Specifications Outdoor Multi:

 

Top of Form

OUTDOOR UNIT                                                                             MU2R15 UL0

Compressor                          Type

Twin Rotary                                                            

Capacity *

Cooling

Min / Nom / Max       kW

0.9 / 4.1 / 4.7

Heating

Min / Nom / Max       kW

1.0 / 4.7 / 5.4                

Low Temperature Capacity  Heating -7°C

Max                            kW

3.3

Power Input *

Cooling

Min / Nom / Max       kW

0.2 / 1.0 / 1.4                                              

Heating

Min / Nom / Max       kW

0.2 / 1.1 / 1.4

Running Current

Cooling

Min / Nom / Max       A

1.1 / 4.6 / 6.4                                                

Heating

Min / Nom / Max       A

1.1 / 4.9 / 6.6

EER

4.14                                                            

COP

4.38

SEER

8.50                                                                

SCOP

4.20

Pdesign (@-10°C)

kW

4.10                                                              

Seasonal Energy Label         Cooling / Heating

A+++ / A+

Annual Energy Consumption  Cooling / Heating

169 / 1,367                                               

Airflow Rate                         Nom

m3/min

28.2

Sound Pressure

Cooling

Nom                           dBA

48                                                                

Heating

Nom                           dBA

51

Sound Power                        Cooling

Max                            dBA

61                                                                

Dimensions                            W x H x D   mm

770 x 545 x 288

Net Weight

Kg

36                                                              

Refrigerant

Type

R32

Charge                                                    Kg

1.1                                                                    

Additional Charge                                    g/m

20

GWP

675                                                             

t-CO2 eq

0.74

Operation Range (Outdoor)

Cooling

Min ~ Max                  °C DB

-10 ~ 48                                                        

Heating

Min ~ Max                  °C WB

-18 ~ 18

Power Supply

Ø / V / Hz

1 / 220-240 / 50                                      

Power Supply Cable

No. x mm2

3C x 2.5

Transmission Cable

No. x mm2

4C x 0.75                                                     

Circuit Breaker

A

15

Piping Length Total

m

30                                                             

Piping Length per Branch

Max                            m

20

Piping Elevation Difference

IDU - ODU

Max                            m

15                                                                

IDU - IDU

Max                            m

7.5

Piping Connection

Liquid                 mm (inch) x No.

Ø6.35 (1/4) x 2                                               

Gas                  mm (inch) x No.

Ø9.52 (3/8) x 2



These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.

Not yet reviewed
Write an online review and share your thoughts with other shoppers!
Be the first to review this product