Hitachi Air Conditioning Summit And Performance Wall Mounted RAK Heat Pump Inverter A++

Hitachi Air Conditioning Wall Mount RAK-35RPD Performance Heatpump 3.5Kw/12000Btu A++ R32 240V~50Hz

Hitachi Air Conditioning Wall Mount RAK-35RPD Performance Heatpump 3.5Kw/12000Btu A++ R32 240V~50Hz

£809.98 £674.98 (ex. VAT)
Stock Status: In Stock
Blog






A++ Energy Rated Product

Includes:


1 x RAK-35RPD R32 Indoor wall unit
1 x RAC-35WPD R32 Outdoor unit
1 x RAR-6N1 Ir remote control



The New Performance R32 Hitachi air conditioning RAK wall mounted range are highly economical and environmentally friendly. Using the latest compressor and inverter technology keeps power consumption to a minimal, but at the same time providing powerful cooling and heating. All Hitachi’s air conditioning units offer high seasonal efficiencies, with models in the Performance range achieving high seasonal performance SCOP A++ 4.6 and SEER A++ 7.6. ​​The compact dimensions of the Performance model (280 x 780 x 218) are common across the entire range and allow for easier integration. Low Noise Levels


Enhanced inverter performance and system performance are achieved by the addition of a ‘Direct Current’ drive compressor, resulting in up to 10% more efficient than standard 'AC' (Alternating Current) Systems. The variable speed compressor (inverter) enables the system to rapidly reach the desired room temperature setting. Once the desired room temperature has been achieved the compressor rotation peed is reduced, saving up to 30% in energy usage (when compared to standard fixed speed systems).


A bigger flap on the indoor unit delivers air quickly to every corner of the room and the powerful, sweeping air flow eliminates dead zones and improves the cooling and heating effect. The trapezoidal fan blades cut the air diagonally to minimise air resistance and the conical blade fan ensures a high airflow. With this diagonal air blow, less friction is caused, which reduces noise and improves efficiency. The fan diameter has been increased from the conventional 90mm to 100mm. Includes deodorising and anti-bacterial Wasabi filters as standard.

Volt Free control of the air conditioning system option, used to turn the unit on/off remotely after receiving a signal such as key-card, door or window switch, specifically useful in hotel rooms to prevent unnecessary use. Accessory SPX WDC3 is required.



Product Key Feature's:
 

  • SCOP A++ 4.6 and SEER A++ 7.6 R32 Inverter Heat Pump
  • Infra-red controller
  • Slim construction 218mm
  • Pipe runs up to 20 meters
  • Low noise 19dBA on low
  • Cold draft prevention on heat pump start up
  • Fault diagnosis
  • Auto re-start after power interruption
  • PRE-CHARGED WITH REFRIGERANT for up to 20 metres pipe length
  • Light weight noise absorbing outdoor unit
  • Volt Free control
  • 5 Years Warranty
 


Technical Specifications:

 

INDOOR R32

Unit

RAK-35RPD

Nominal capacity adjustable

no

Nominal Cooling capacity (min - max)

kW

3.50 (0.90- 4.00)

Cooling sensible capacity

kW

2.42

Nominal Heating capacity (min - max)

kW

4.20 (0.90- 5.00)

Noise level cooling (sound pressure) (SL / L / M / H)

dB(A)

25/26/36/43

Noise level heating (sound pressure) (SL / L / M / H)

dB(A)

26/27/36/44

Noise level (sound power)

dB(A)

57

Air flow cooling mode (SL / L / M / H)

m3/h

353 / 420 / 485 / 680

Air flow heating mode (SL / L / M / H)

m3/h

363 / 480 / 570/ 780

Fan Motor

W

30

Dehumidification

l/h

1.6

Dimensions (H x W x D)

mm

280 x 780 x 230

Weight

kg

8.5

Colour

Star White (N9.3)

Condensate Drain

mm

φ 16

Running current (C/H)

A

1.09-6.35/1.09-7.39

Power supply

220-230V

Cable section (interconnection

mm²

1.50x 3+EARTH/-

Piping diameter (Liq / Gas)

Inch

1/4" / 3/8"

Drain diameter (ext)

mm

φ 16

Remote control (standard/optional)

RAR-6N1/SPX-RCDB

Filter

ACL Filter

activated carbon

ACL part name

SPX-CFH25

Pre-filter(Standard/Optional )

WASHABLE/

Stainless-SPX-SPF8

OUTDOOR R32

RAC-35WPD

Nominal Cooling capacity (min - max)

kW

3.50 (0.90- 4.00)

Nominal Heating capacity (min - max)

kW

4.20 (0.90- 5.00)

Nominal cooling power input (min - max)

kW

0.941(0.25 - 1.46)

Nominal heating power input (min - max)

kW

1.000(0.25 - 1.70)

EER / COP

3.72/4.2

SEER / SCOP

7.80/4.90

Energy class (SEER/SCOP)

A++/A++

Noise level cooling (sound pressure)

dB(A)

48

Noise level heating (sound pressure)

dB(A)

49

Noise level (sound power)

dB(A)

61

Air flow (Cooling / Heating)

m3/h

1920 / 1620

Dimensions (H x W x D)

mm

548× 750× 288

Weight

kg

32.5

Colour (Munsell Code)

Beige (5Y7/2)

Power supply

V/Ph/Hz

230V / 1Ph / 50Hz

Recommended fuse size

A

15

Starting current(C/H)

A

4.81/5.11

Running current (C/H)

A

1.09-6.35/1.09-7.39

Cable section (power)

mm²

1.50x 2+EARTH

Cable section (Interconnection)

mm²

1.50x 3+EARTH

Piping diameter (Liq / Gas)

Inch

1/4" / 3/8"

Minimum piping length

m

3

Maximum piping length / height difference

m

20 / 10

Current quantity of refrigerant / Chargeless

kg

0.870

Chargeless length / Additional refrigerant

charge

m / g/m

20/-

Working range (cooling / heating)

° C

-10~43/-15~21

Refrigerant

R32

Condenser Fan

Propeller Fan

Compressor

Type

ROTARY

Oil Charge

mL

320±20

Oil Type

ACS-68R or equivalent

Coil resistance

Ω

2.167 at 20

Quantity

1




 



PDF Data:





These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.
Not yet reviewed
Write an online review and share your thoughts with other shoppers!
Be the first to review this product