Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Fujitsu Air Conditioning AUXG-KRLB Circular Blow Cassette Heat Pump Inverter

Fujitsu Air Conditioning AUXG54LRLB Circular Flow Cassette Heat pump Inverter (14 kW/54000Btu) 240V~50Hz

Fujitsu Air Conditioning AUXG54LRLB Circular Flow Cassette Heat pump Inverter (14 kW/54000Btu) 240V~50Hz

£2,852.83 £2,377.36 (ex. VAT)
Stock Status: Sold Out
Sorry, this item is out of stock
Blog


The Advanced Fujitsu air conditioning AUXG CIRCULAR FLOW cassette range has now been extended to include new smaller capacity INVERTER system starting at 5kW / 17000Btu, and an high efficiency system 16kW / 54000Btu at the top end of the range. The new touch screen 7-Day Programmable Timer now included in standard controls specification and multi programmable 24Hr control. Fujitsu air conditioning and heat pump high performance inverter compact cassette series split systems designed for residential and commercial application such as offices, shops, meeting rooms, restaurants, hotels, clubs, gyms, and open plan areas.

The New Cassette type realizes Circular Flow to blow large airflow in 360º direction by mounting high performance DC fan motor, new turbo fan and unique seamless airflow louver design. Each louver can be set individually by Touch Panel Wired Remote Controller to enjoy the comfort of different directional airflow's according to various room layouts. Energy saving operation starts automatically by detecting the motion of a person. 2 modes of save operation mode and stop mode can be selected.

In order to be able to adapt to the shape of the room to be conditioned, the Fujitsu air conditioning cassette units are able to configure the air impulsion in two, three or four different directions and thus achieve uniform air conditioning. The unit can make a sweep using its deflector slats to air-condition the premises more quickly. The direction of the sweep as well as the auto swing function can be selected by using the remote control. Models with a movable rosette incorporate weekly programming control that allows on and off programming up to twice a day. 


Auto Changeover: The air conditioner will switch automatically from cooling to heating modes depending on the set temperature. Optimized Cooling & Heating Air Flow: The air vanes will be adjusted according to the mode of operation. In heating mode air will be distributed at a lower angle due to hot air rising. Swirl Swing: Swirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the louvers.


Product Key Feature's


• High Head Drain Pump 850mm
• Auto Changeover (heating and cooling)
• Low Standby Power (switch mode)
• Auto Restart after power outage
• Easy-to-Clean Air Filter
• Two Thermistor Temperature Control (Controller and Unit)
• Optimal Louver Air Distribution control
• Auto Operation
• Quiet Operation
• Healthy De-humidification
• Hot Start on heat mode
• 24-Hour ON/OFF Setting Timer With Weekly Program 
• Optimal air distribution with a directional Air flow system.
• Auto Louver Swing


Other Controller Features

- New multi programming of different operating schedules each day.
- On and off programming over the day.
- Set the time in periods of five minutes.
- Cancellation of operation on a specific day (public holiday)


 


Technical Data

Model No.

Indoor unit

AUXG45LRLB

AUXG54LRLB

Outdoor unit

AOYG45LBTA

AOYG54LBTA

Power Source

Single-phase, ~230V, 50Hz

Capacity

Cooling

kW

12.5 (4.0-14.0)

13.3 (4.5-14.5)

Heating

14.0 (4.2-16.2)

15.8 (4.7-16.5)

Input Power

Cooling/Heating

kW

3.85/3.73

4.38/4.58

EER

Cooling

W/W

3.25

3.04

COP

Heating

3.75

3.45

Pdesign

Cooling/Heating(-10°C)

kW

-

-

SEER

Cooling

W/W

-

-

SCOP

Heating (Average)

-

-

(QHUJ\  (IÀFLHQF\

Class

Cooling

-

-

Heating (Average)

-

-

Max. Operating Current

Cooling/Heating

A

20.5/20.5

21.5/21.5

Annual Energy Consumption

Cooling

kWh/a

-

-

Heating

-

-

Moisture Removal

I/h

4.5

5.0

Sound Pressure Level

Indoor (Cooling)

H/M/L/Q

dB(A)

46/42/39/35

47/43/40/36

Indoor (Heating)

H/M/L/Q

46/42/39/35

47/43/40/36

Outdoor(Cooling/Heating)

High

55/55

55/57

Sound Power Level

Indoor(Cooling/Heating)

High

60/60

61/61

Outdoor(Cooling/Heating)

High

68/68

69/71

$LUÁRZ 5DWH

Indoor / Outdoor

High

m3/h

2000/6750

2100/6750

Net Dimensions H x W x D Weight

Indoor

mm

288×840×840

288×840×840

kg(lbs)

29 (64)

29 (64)

Outdoor

mm

1290×900×330

1290×900×330

kg(lbs)

86 (189)

86 (189)

Connection Pipe Diameter (Liquid / Gas)

mm

9.52/15.88

9.52/15.88

Drain hose Diameter (I.D./O.D.)

25/32

25/32

Max Pipe Length (Pre-Charge)

m

50 (20)

50 (20)

Max Height Difference

30

30

Operation Range

Cooling

°CDB

-15 to 46

-15 to 46

Heating

-15 to 24

-15 to 24

Refrigerant

Type (Global Warming Potential)

R410A (2,088)

R410A (2,088)

Charge

g

3,350

3,350

Cassette Grille

(to be ordered separately)

Model name

UTG-UKYA-W

UTG-UKYA-W

Dimensions (H × W × D)

mm

53×950×950

53×950×950

Weight

kg(lbs)

6.0 (13)

6.0 (13)

System List Price

£

3033

3522



PDF Data Sheet:





These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.

Write an online review and share your thoughts with other shoppers!