Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Fujitsu Air conditioning ASYG-KM Wall Mounted Standard Series

Fujitsu Air conditioning ASYG30KMTA Wall Mounted Heat Pump Inverter A++ 8Kw/30000Btu 240V~50Hz

Fujitsu Air conditioning ASYG30KMTA Wall Mounted Heat Pump Inverter A++ 8Kw/30000Btu 240V~50Hz

£2,031.56 £1,692.97 (ex. VAT)
Stock Status: In Stock

Fujitsu Air conditioning ASYG30KMTA Wall Mounted Heat Pump Inverter A++ 8Kw/30000Btu 240V~50Hz

Includes:

1 Piece of ASYG30KMTA Wall Mounted

1 Piece of AOYG30KMTA Outdoor Unit

1 Piece of Ir Controller 

Large capacity and powerful airflow over a large heat exchanger, long cross-flow fan, high output DC fan motor and a new airflow structure design. 


 

The ASYG wall mounted Fujitsu air conditioner is a people-friendly, function packed, environment-friendly range of heating and cooling systems. The Fujitsu ASYG wall mounted units offer a broad range of functions designed for large living spaces, offices, bedrooms and children’s rooms. Fujitsu air conditioners make the room being air conditioned more comfortable with automatic operation functions, air cleaning filters and easy control functions. All Fujitsu air conditioner models feature heat pump inverter technology which are highly efficient in operation and conserve electricity usage.


The Fujitsu air conditioning ASYG-KMTA has a attractive new flat front panel design on the indoor units which provides easier cleaning as the air return remains hidden at the top and the front fascia has no air inlet. The unit is a slim-line construction only 203mm deep and has a high density heat exchanger which optimises and enhances the flow/K calories ratio to the air and produces very little noise (31dB@1meter). Because of this design the turbine fan is able to work at a lower speed and minimises noise. The fully functional modern IR type remote control comes as standard with a optional wi-fi available soon.

The Fujitsu air conditioning ASYG-KMTA outdoor unit is made from lightweight material, are smaller and weigh less whilst the  rigid construction, quality  and control system increasing their resistance and optimised power rating in any outside weather conditions. Among the many qualities of outdoor unit's body design is the noise reduction as a result of the material absorption of vibrations, noise and the incorporation of protection of the connection valves so all condensate can be dispersed into a single drain out point.

 The ASYG-KMTA model has a server room function with inter-lock operation by connecting 2 indoor units with a cable. Cooling operation can be performed even in low outdoor temperatures and low humidity environments.  The Alternative operation where two units operate alternately, When 1 unit breaks down, the other unit starts operating automatically. Both units operate simultaneously when the loaded capacity is not enough with one unit. 

The human sensor function catches movements of people in a room and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to previous operating mode.

 


Product Key Feature's:



• High SCoP, up to record 4.5
• Infra-red controller    
• Slim construction 340mm
• Pipe runs up to 50 metres
• Low noise – 31dBA on low
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 30 metres pipe length
• Low ambient tested to -15 Deg/C in heating.
• Light weight noise absorbing outdoor unit.


 


 

Technical Data:

Power Source

Single phase, ~230V, 50Hz

Capacity

Cooling

kW

8.0 (2.9-9.0)

Heating

8.8(2.2-11.0)

UK Total/sensible cooling

kW

7.55 / 8.87

Input Power

Cooling/Heating

kW

2.33/2.20

EER

Cooling

W/W

3.43

COP

Heating

4.00

Pdesign

Cooling/Heating(-10°C)

kW

8.0/6.5

SEER

Cooling

W/W

6.67

SCOP

Heating (Average)

4.54

(QHUJ\   (IÀFLHQF\

Class

Cooling

A++

Heating (Average)

A+

Annual Energy Consumption

Cooling

kWh/a

419

Heating

2,001

Moisture Removal

I/h

2.6

Sound Pressure Level

Indoor (Cooling)

H/M/L/Q

dB(A)

50/44/40/33

Indoor (Heating)

H/M/L/Q

49/44/39/33

Outdoor(Cooling/Heating)

High

53/55

Sound Power Level

Indoor(Cooling/Heating)

High

65/65

Outdoor(Cooling/Heating)

High

68/69

$LUÁRZ 5DWH

Indoor/Outdoor (Cooling)

High

m3/h

1,330/3,750

Indoor/Outdoor (Heating)

High

1330/3750

Net Dimensions H x W x D

Indoor

mm

340x1150x280

Outdoor

mm

788x940x320

Weight

Indoor

kg(lbs)

18.5(41)

Outdoor

kg(lbs)

52.0(115)

Remote Controller Type (Supplied With Unit)

Wireless

Interconnecting Cable (Suggested cable size 1.5mm)

3 Core + Earth

Suggested MCB Size

Amp

25

Max. Operating Current

Cooling/Heating

A

21.0/21.0

Power Supply To

Outdoor

Connection Pipe Diameter (Gas / Liquid)

Inch

5/8 & 3/8

Max Pipe Length (Pre-Charge)

m

50(30)

Max Height Difference

30

Refrigerant

Type

R32

Charge

g

1900

Additional Charge

g/m

40

Operation Range

Cooling

°CDB

-15to46

Heating

-15to24

Optional parts:

Compact Wired Remote Controller: UTY-RCRYZ1

External Input and Output PCB: UTY-XCSXZ2

Network Converter for single split (DC power supply type): UTY-VTGX

Wired Remote Controller (Touch Panel): UTY-RNRYZ3

Communication Kit: UTY-TWRXZ2

Network Converter for single split (AC power supply type): UTY-VTGXV

Simple Remote Controller (Without operation mode):  UTY-RHRY

Wireless LAN Interface: UTY-TFSXF2

Wireless interface for use with Smart home products:   FJ-AC-WIFI-1

Simple Remote Controller: UTY-RSRY

External Connect Kit: UTY-XWZXZ5

Network Converter for single split (DC power supply type): UTY-VTGX

Communication Kit: UTY-TWRXZ2

Wireless LAN Interface: UTY-TFSXF2

External Switch Controller: UTY-TERX

KNX® Converter: UTY-VKSX*

MODBUS® Converter: UTY-VMSX*

PDF Data Sheet:



PDF Data Sheet


These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.

Not yet reviewed
Write an online review and share your thoughts with other shoppers!
Be the first to review this product