Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Daikin Air Conditioning Altherma Air Source Heat Pump

Daikin UK.MONO5GROUND Air-Water Low Temperature Monoblock Heat Pump 5Kw/18000Btu A++ 240V~50Hz

Daikin UK.MONO5GROUND Air-Water Low Temperature Monoblock Heat Pump 5Kw/18000Btu A++ 240V~50Hz

£3,795.27 £3,162.72 (ex. VAT)
Stock Status: In Stock
Blog
Daikin UK.MONO5GROUND EDLQ05CV3 Air to Water Low Temperature Monoblock Heat Pump 5Kw/18000Btu A++ R32 240V~50Hz

This Kit Includes:

 

UK.MONO5GROUND

5kW ground mounted configuration for heating and hot water containing:

£2,614.00

EDLQ05CV3                           5kW outdoor unit (heating only)

£2,127.00

EKCB07CV3                           Wiring centre

£252.00

EKRUCBL2                             User interface

£100.00

K.FF600ASN                          Pair of flexi feet

£55.00

K.HOSE750                            Pair of flexible hoses 750mm

£80.00

This unit is used for both heating and cooling applications. The unit can be combined with Daikin fan coil units, floor heating applications, low temperature radiators, domestic hot water tank (option) and Daikin solar kit (option). A remote controller is standard supplied with the unit to control your installation. Heating/cooling units and heating only units The unit range consists of two main versions: a heating/cooling (EB) version and a heating only (ED) version.
The units are delivered with an integrated backup heater for additional heating capacity during low outdoor temperatures. The backup heater also serves as a backup in case of malfunctioning of the unit and for freeze protection of the outside water piping during winter time. The backup heater factory set capacity is 6 kW, however, depending on the installation, the installer can limit the backup heater capacity to 3 kW/2 kW. The backup heater capacity decision is a mode based on the equilibrium temperature,
An optional domestic hot water tank can be connected to the unit. The domestic hot water tank is available in 2 types: tank with built-in electrical booster heater (EKHW*) in 3 different sizes: 150, 200 and 300 litre, tank without electrical booster heater (EKHTS) in 2 different sizes: 200 and 260 litre. An optional room thermostat EKRTW, EKRTWA, or EKRTR can be connected to the unit. Refer to the installation manual of the room thermostat for more information. To obtain more information concerning these option kits, please refer to dedicated installation manuals of the kits.
 
Key Product Features:

Outdoor Unit

EDLQ05CV3

Trade Unit Price

£2127.00

User Interface (must be ordered separately)

EKRUCBL2

Description

5kW, 1-phase, 230V

Function

Heating Only

Dimensions                                   Height x Width x Depth     mm

735 × 1090 × 350

Weight                                                                                          kg

76

Capacity                                            Heating (a/b)                        kW

4.40 / 4.03

Input                                                 Heating (a/b)                        kW

0.88 / 1.13

COP

5.00 / 3.58

Seasonal space heating efficiency

Space heating (Average climate) 35°C

Class

A++

Efficiency

172

SCOP

4.39

Space heating (Average climate) 55°C

Class

A++

Efficiency

125

SCOP

3.20

Operation Range

Heating                                  °C

-25 ~ +25

Hot Water                              °C

-25 ~ +35

Sound pressure/Power level                                                          dBA

48 / 61

Refrigerant charge                          R-410A                                   kg

1.30

Power supply

1-phase / 230V / 50Hz

Recommended Fuses                                                                      Amps

16

Pump                                                 No. of speeds

Inverter Controlled

Expansion vessel volume                                                               litres

7

Water connections                         Diameter                               Inch

1” (male)

Max piping length OU to cylinder                                                 mm

10

Minimum water volume without back-up heater                     litres

20

Minimum water volume with back-up heater                           litres

10

BACK UP HEATER KIT (OPTIONAL)

EKMBUHC3V3

Description

Back up heater kit (3kW)

Trade Unit Price

£517.00

Nominal rating

kW

3

Dimensions

Depth                                     mm

210

Width

mm

250

Height

mm

560

Power supply

1-phase / 230V / 50Hz

Recommended fuses

3 kW 1ph 230V

Amps

16

Water connections

Diameter

inch

1” (male)

Accessories: 

Accessory Ref

Description

Trade Price

EKRUCBL2

User interface

£100.00

EKRUCBS

Optional simplified room thermostat

£94.00

EKPCCAB4

PC cable – to upload field settings from PC to unit or spare controller

£215.00

EKRSC1

Optional remote outdoor temperature sensor (see note)

£71.00

KRCS01-1

Optional remote indoor temperature sensor (see note)

£54.00

EK2CB07CV3

Optional Wiring centre - for remote alarm monitoring, run and fault indication and bivalent operation

£252.00

K.FF600ASN

Pair of flexi feet to mount the outdoor unit

£55.00

K.CWBXL

Wall mounting brackets for outdoor units (250kg, 660mm long)

£81.00

K.DT2

Condensate drip tray for use with K.CWBXL

£68.00

K.HOSE750

Pair of flexible hoses (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression)

£80.00

K.HOSE750EL

Pair of flexible hoses with elbow (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression)

£114.00

K.CG750S

Outdoor unit guard

£326.00

K.FERNOXTF1

Fernox magnetic filter 1”

£110.00

K.FERNOXTF1FL

Fernox magnetic filter 1” and F1 inhibitor fluid (500ml)

£129.00

BRP069A62

Smart Comfort Controller

£143.00

K.ELECMETV

Electric meter for domestic RHI - Single-phase (Metering for performance compliant)

MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump

£129.00

K.ELECMETW

Electric meter for domestic RHI - Three-phase (Metering for performance compliant)

MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump

£230.00

EKUMBPART

3rd party tank connection kit - Dry pocket sensor

£210.00


 






PDF Data:


 



These units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.



 
Not yet reviewed
Write an online review and share your thoughts with other shoppers!
Be the first to review this product