Daikin Air Conditioning Altherma Air Source Heat Pump Home / Air Conditioning / Daikin Air Conditioning / Daikin Air Conditioning Altherma Air Source Heat Pump / Daikin UK.MONO5GROUND Air-Water Low Temperature Monoblock Heat Pump 5Kw/18000Btu A++ 240V~50Hz Daikin UK.MONO5GROUND Air-Water Low Temperature Monoblock Heat Pump 5Kw/18000Btu A++ 240V~50Hz Daikin UK.MONO5GROUND Air-Water Low Temperature Monoblock Heat Pump 5Kw/18000Btu A++ 240V~50Hz £3,795.27 £3,162.72 (ex. VAT) Stock Status: In Stock Information Reviews Daikin UK.MONO5GROUND EDLQ05CV3 Air to Water Low Temperature Monoblock Heat Pump 5Kw/18000Btu A++ R32 240V~50Hz This Kit Includes: UK.MONO5GROUND 5kW ground mounted configuration for heating and hot water containing: £2,614.00 EDLQ05CV3 5kW outdoor unit (heating only) £2,127.00 EKCB07CV3 Wiring centre £252.00 EKRUCBL2 User interface £100.00 K.FF600ASN Pair of flexi feet £55.00 K.HOSE750 Pair of flexible hoses 750mm £80.00 This unit is used for both heating and cooling applications. The unit can be combined with Daikin fan coil units, floor heating applications, low temperature radiators, domestic hot water tank (option) and Daikin solar kit (option). A remote controller is standard supplied with the unit to control your installation. Heating/cooling units and heating only units The unit range consists of two main versions: a heating/cooling (EB) version and a heating only (ED) version. The units are delivered with an integrated backup heater for additional heating capacity during low outdoor temperatures. The backup heater also serves as a backup in case of malfunctioning of the unit and for freeze protection of the outside water piping during winter time. The backup heater factory set capacity is 6 kW, however, depending on the installation, the installer can limit the backup heater capacity to 3 kW/2 kW. The backup heater capacity decision is a mode based on the equilibrium temperature, An optional domestic hot water tank can be connected to the unit. The domestic hot water tank is available in 2 types: tank with built-in electrical booster heater (EKHW*) in 3 different sizes: 150, 200 and 300 litre, tank without electrical booster heater (EKHTS) in 2 different sizes: 200 and 260 litre. An optional room thermostat EKRTW, EKRTWA, or EKRTR can be connected to the unit. Refer to the installation manual of the room thermostat for more information. To obtain more information concerning these option kits, please refer to dedicated installation manuals of the kits. Key Product Features: Outdoor Unit EDLQ05CV3 Trade Unit Price £2127.00 User Interface (must be ordered separately) EKRUCBL2 Description 5kW, 1-phase, 230V Function Heating Only Dimensions Height x Width x Depth mm 735 × 1090 × 350 Weight kg 76 Capacity Heating (a/b) kW 4.40 / 4.03 Input Heating (a/b) kW 0.88 / 1.13 COP 5.00 / 3.58 Seasonal space heating efficiency Space heating (Average climate) 35°C Class A++ Efficiency 172 SCOP 4.39 Space heating (Average climate) 55°C Class A++ Efficiency 125 SCOP 3.20 Operation Range Heating °C -25 ~ +25 Hot Water °C -25 ~ +35 Sound pressure/Power level dBA 48 / 61 Refrigerant charge R-410A kg 1.30 Power supply 1-phase / 230V / 50Hz Recommended Fuses Amps 16 Pump No. of speeds Inverter Controlled Expansion vessel volume litres 7 Water connections Diameter Inch 1” (male) Max piping length OU to cylinder mm 10 Minimum water volume without back-up heater litres 20 Minimum water volume with back-up heater litres 10 BACK UP HEATER KIT (OPTIONAL) EKMBUHC3V3 Description Back up heater kit (3kW) Trade Unit Price £517.00 Nominal rating kW 3 Dimensions Depth mm 210 Width mm 250 Height mm 560 Power supply 1-phase / 230V / 50Hz Recommended fuses 3 kW 1ph 230V Amps 16 Water connections Diameter inch 1” (male) Accessories: Accessory Ref Description Trade Price EKRUCBL2 User interface £100.00 EKRUCBS Optional simplified room thermostat £94.00 EKPCCAB4 PC cable – to upload field settings from PC to unit or spare controller £215.00 EKRSC1 Optional remote outdoor temperature sensor (see note) £71.00 KRCS01-1 Optional remote indoor temperature sensor (see note) £54.00 EK2CB07CV3 Optional Wiring centre - for remote alarm monitoring, run and fault indication and bivalent operation £252.00 K.FF600ASN Pair of flexi feet to mount the outdoor unit £55.00 K.CWBXL Wall mounting brackets for outdoor units (250kg, 660mm long) £81.00 K.DT2 Condensate drip tray for use with K.CWBXL £68.00 K.HOSE750 Pair of flexible hoses (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression) £80.00 K.HOSE750EL Pair of flexible hoses with elbow (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression) £114.00 K.CG750S Outdoor unit guard £326.00 K.FERNOXTF1 Fernox magnetic filter 1” £110.00 K.FERNOXTF1FL Fernox magnetic filter 1” and F1 inhibitor fluid (500ml) £129.00 BRP069A62 Smart Comfort Controller £143.00 K.ELECMETV Electric meter for domestic RHI - Single-phase (Metering for performance compliant) MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump £129.00 K.ELECMETW Electric meter for domestic RHI - Three-phase (Metering for performance compliant) MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump £230.00 EKUMBPART 3rd party tank connection kit - Dry pocket sensor £210.00 PDF Data: These units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015. Not yet reviewed Write an online review and share your thoughts with other shoppers! Be the first to review this product Related Products Panasonic Aquarea Air to Water Heat Pump Split System (7kW to 16kW) 240V~50Hz £4,035.95 £3,363.29 (ex. VAT) Panasonic Aquarea WH-MDC-G3E5 Air to Water Heat Pump Monobloc Systems 240V~50Hz £4,447.87 £3,706.56 (ex. VAT) Land Based Wind Turbine Installation Kit 250W With 6.4Meter Tower £2,399.00 £1,999.17 (ex. VAT) Therma V Air Heat Pump Model: AHUW126A0 + H12SNE (12 kW / 40000 btu) 240V~50Hz £4,160.30 £3,466.92 (ex. VAT) Panasonic Aquarea WH-MXC-GE5 Air to Water Heat Pump Monobloc Systems A++ 240V/415V~50Hz £4,686.60 £3,905.50 (ex. VAT) Panasonic Aquarea WH-MHF-GE5 Air to Water Heat Pump Monobloc HT High Temp A++ 240V/415V~50Hz £4,942.43 £4,118.69 (ex. VAT) Daikin EDLQ011CV3 Air to Water Low Temperature Monoblock Heat Pump 11Kw/37000Btu A++ 240V~50Hz £4,657.69 £3,881.41 (ex. VAT) Daikin EVLQ-CV3 Hybrid Heat-Pump Boiler System Installation Kit 240V~50Hz £6,436.18 £5,363.48 (ex. VAT) Daikin UK.MONO5 EDLQ05CV3 Air to Water Low Temperature 5Kw/18000Btu A++ 240V~50Hz £3,599.25 £2,999.38 (ex. VAT) Daikin UK.MONO7 EDLQ07CV3 Air-Water Low Temperature Monoblock Heat Pump 7Kw/24000Btu A++ 240V~50Hz £4,114.68 £3,428.90 (ex. VAT) Daikin UK.MONO7GROUND EDLQ07CV3 Ground to Water Monoblock Heat Pump 7Kw/24000Btu A++ 240V~50Hz £4,310.68 £3,592.23 (ex. VAT) Panasonic Aquarea Air to Water Heat Pump Split System (9kW to 16kW) A++ 415V~50Hz £6,406.42 £5,338.68 (ex. VAT) Panasonic Aquarea All In One WH-ADC-H3E5 Air to Water Heat Pump Split 9kW to 16kW A++ 240V~50Hz £6,687.87 £5,573.23 (ex. VAT) Hitachi AquaFree RWM 4.0FSN1E heat-pump boiler (14.6 kW / 50000 Btu) 240V~50Hz £9,674.94 £8,062.45 (ex. VAT)