Daikin EBLQ011CV1 Air to Water Low Temperature Monoblock Heat Pump 11Kw/37000Btu A+ 415V~50Hz HEATING AND COOLING
This Kit Includes:
1 X EDLB011CV1 HEATING AND COOLING 415V~50Hz Outdoor heat pump
1 x EKCB07CV3 Wiring Centre
1 x EKRUCBL2 - User interface
This unit is used for both heating and cooling applications. The unit can be combined with Daikin fan coil units, floor heating applications, low temperature radiators, domestic hot water tank (option) and Daikin solar kit (option). A remote controller is standard supplied with the unit to control your installation. Heating/cooling units and heating only units The unit range consists of two main versions: a heating/cooling (EB) version and a heating only (ED) version.
The units are delivered with an integrated backup heater for additional heating capacity during low outdoor temperatures. The backup heater also serves as a backup in case of malfunctioning of the unit and for freeze protection of the outside water piping during winter time. The backup heater factory set capacity is 6 kW, however, depending on the installation, the installer can limit the backup heater capacity to 3 kW/2 kW. The backup heater capacity decision is a mode based on the equilibrium temperature,
An optional domestic hot water tank can be connected to the unit. The domestic hot water tank is available in 2 types: tank with built-in electrical booster heater (EKHW*) in 3 different sizes: 150, 200 and 300 litre, tank without electrical booster heater (EKHTS) in 2 different sizes: 200 and 260 litre. An optional room thermostat EKRTW, EKRTWA, or EKRTR can be connected to the unit. Refer to the installation manual of the room thermostat for more information. To obtain more information concerning these option kits, please refer to dedicated installation manuals of the kits.
Key Product Features:
Outdoor Unit
|
3 Phase
|
EBLQ011CW1
|
Trade Unit Price
|
£3,467.00
|
User Interface (must be ordered separately)
|
EKRUCBL2
|
Description
|
11kW,
3-phase, 400V
|
Function
|
Reversible
|
Dimensions Height x Width x Depth mm
|
1348 x 1160 x 380
|
Weight kg
|
154
|
Nominal capacity
|
Heating (a/b) kW
|
11.2 / 11.0
|
Cooling kW
|
12.4
|
Nominal input Heating (a/b) kW
|
2.43 / 3.10
|
COP Heating (a/b)
|
4.61 / 3.55
|
Seasonal space heating efficiency
|
Space heating (Average climate) 35°C
|
Class
|
A++
|
Efficiency
|
156
|
SCOP
|
3.98
|
Space heating (Average climate) 55°C
|
Class
|
A+
|
Efficiency
|
120
|
SCOP
|
3.09
|
EER Cooling
|
2.63
|
Operation range
|
Heating* °C
|
-10 ~ +35
|
Cooling °C
|
10 ~ 46
|
Hot water °C
|
-25 ~ +35
|
Sound pressure / power level
|
Heating dBA
|
51 / 64
|
Cooling dBA
|
50 / 64
|
Refrigerant charge (factory) R-410A kg
|
3.40
|
Power supply
|
3-phase / 400V / 50Hz
|
Recommended fuses Outdoor unit A
|
20
|
Pump No. of speeds
|
Inverter controller
|
Expansion vessel volume litres
|
10
|
Water connections (diameter) inches
|
1” (male)
|
Max piping length OU to cylinder m
|
10
|
Minimum water volume without back-up heater litres
|
80
|
Minimum water volume with back-up heater litres
|
20
|
Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35)
Heating b: Ambient air temperature 7°C and leaving water temperature 45°C (A7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit
Notes:
i) User interface (EKRUCBL2) must be ordered with every EDLQ011-016
BACK UP HEATER KIT (RECOMMENDED)
|
EKMBUHC3V3
|
EKMBUHC9W1**
|
Description
|
Back up heater kit (3kW)
|
Back up heater kit (3/6/9kW)
|
Trade Unit Price
|
£517.00
|
£576.00
|
Nominal rating
|
|
kW
|
3
|
3-6
|
Dimensions
|
Depth
|
mm
|
210
|
Width
|
mm
|
250
|
Height
|
mm
|
560
|
Power supply
|
1-phase / 230V / 50Hz
|
3-phase / 400V / 50Hz
|
fuses
|
3 kW 1ph 230V
|
Amps
|
16
|
6 kW 1ph 230V
|
Amps
|
-
|
32***
|
6kW 3ph 400V
|
Amps
|
-
|
10***
|
9kW 3ph 400V
|
Amps
|
-
|
16***
|
Water connections
|
Diameter
|
inch
|
1” (male)
|
Accessories:
Accessory Ref
|
Description
|
Trade Price
|
EKRUCBL2
|
User interface
|
£100.00
|
EKRUCBS
|
Optional simplified room thermostat
|
£94.00
|
EKPCCAB4
|
PC cable – to upload field settings from PC to unit or spare controller
|
£215.00
|
EKRSC1
|
Optional remote outdoor temperature sensor (see note)
|
£71.00
|
KRCS01-1
|
Optional remote indoor temperature sensor (see note)
|
£54.00
|
EK2CB07CV3
|
Optional Wiring centre - for remote alarm monitoring, run and fault indication and bivalent operation
|
£252.00
|
K.FF600ASN
|
Pair of flexi feet to mount the outdoor unit
|
£55.00
|
K.CWBXL
|
Wall mounting brackets for outdoor units (250kg, 660mm long)
|
£81.00
|
K.DT2
|
Condensate drip tray for use with K.CWBXL
|
£68.00
|
K.HOSE750
|
Pair of flexible hoses (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression)
|
£80.00
|
K.HOSE750EL
|
Pair of flexible hoses with elbow (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression)
|
£114.00
|
K.CG750S
|
Outdoor unit guard
|
£326.00
|
K.FERNOXTF1
|
Fernox magnetic filter 1”
|
£110.00
|
K.FERNOXTF1FL
|
Fernox magnetic filter 1” and F1 inhibitor fluid (500ml)
|
£129.00
|
BRP069A62
|
Smart Comfort Controller
|
£143.00
|
K.ELECMETV
|
Electric meter for domestic RHI - Single-phase (Metering for performance compliant)
MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump
|
£129.00
|
K.ELECMETW
|
Electric meter for domestic RHI - Three-phase (Metering for performance compliant)
MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump
|
£230.00
|
EKUMBPART
|
3rd party tank connection kit - Dry pocket sensor
|
£210.00
|