Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Daikin Applied Packaged Water-cooled Water Chillers

Daikin Applied Packaged Water-cooled Water Chillers EWWQ049KBW1N 47Kw/160000Btu 415V~50Hz

Daikin Applied Packaged Water-cooled Water Chillers EWWQ049KBW1N 47Kw/160000Btu 415V~50Hz

£7,778.00 £6,481.67 (ex. VAT)
Stock Status: In Stock
Blog
Daikin Applied Packaged Water-cooled Water Chillers EWWQ049KBW1N 47Kw/160000Btu 415V~50Hz
 
Super compact dimensions: 600x600x600 mm, reduced energy consumption and low noise. The unit has a stainless steel plate heat exchanger and can be extended up to 183Kw of rated power output. The EWWQ gives you ease of installation and maintenance and the digital controller offers ease of use in selection of cooling or heating. Water filter, flow switch, air purge and integrated pressure sockets included and the micro C & SE controller advanced for direct connection to the Modbus BMS (or to another remote user interface).

 
Key Product Data:

 
  • Simple installation
  • No F-gas qualification needed for installation
  • Daikin inverter technology 
  • Cooling Only
  • One of the most compact units on the market
  • Daikin scroll compressor
  • Electronic DDC controller
  • Low operating sound level
  • Low energy consumption
  • Low refrigerant volume
  • Easy installation and maintenance
  • Stainless steel plate heat exchanger
  • Standard integrated: main switch, pressure ports, flow switch, filter, shutoff valves and air purge
  • 3 Phase 415V~50Hz


 
 

Technical data:

 

Model:

EWWQ049KBW1N

Cooling capacity

Nom.

kW

47.15

Capacity control

Method

Fixed

Minimum capacity

%

50

Power input

Cooling

Nom.

kW

11.42

EER

4.127

ESEER

4.56

IPLV

5.36

Dimensions

Unit

Depth

mm

1,200

Height

mm

600

Width

mm

600

Weight

Unit

kg

310

Operation weight

kg

320

Casing

Colour

Ivory white

Material

Painted galvanized steel plate

Water heat exchanger - evaporator

Type

Brazed plate

Fluid

Water

Fouling factor

0

Water volume

l

4.5

Water temperature in

Cooling

°C

12

Water temperature out

Cooling

°C

7

Water flow rate

Nom.

l/s

2.26

Water pressure drop

Cooling

Nom.

kPa

24.3

Insulation material

Closed cell

Water heat exchanger - condenser

Type

Brazed plate

Fluid

Water

Fouling factor

0

Water volume

l

5.45

Water temperature in

Cooling

°C

30

Water temperature out

Cooling

°C

35

Water flow rate

Nom.

l/s

2.78

Water pressure drop

Cooling

Nom.

kPa

26.9

Compressor

Type

Scroll compressor

Oil

Charged volume

l

6

Quantity

2

Sound power level

Cooling

Nom.

dBA

67

Sound pressure level

Cooling

Nom.

dBA

53

Operation range

Evaporator

Cooling

Min.

°CDB

Max.

°CDB

Condenser

Cooling

Min.

°CDB

Max.

°CDB

Refrigerant

Type

R-410A

Charge

kg

4.6

Circuits

Quantity

2

Piping connections

Evaporator water inlet/outlet (OD)

G1" 1/2

Condenser water inlet/outlet (OD)

G1" 1/2

General

Supplier/Manufacturer details

Name and address

Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark

Daikin Europe N.V.

Product description

Air-to-water heat pump

No

Brine-to-water heat pump

No

Heat pump combination heater

No

Low-temperature heat pump

No

Supplementary heater integrated

No

Water-to-water heat pump

Yes

LW(A) Sound power level (according to EN14825)

dB(A)

67

Space heating general

Other

Cdh (Degradation heating)

0.9

Space heating

Average climate water outlet 35°C

General

Annual energy consumption

kWh

27,290

Ƞs (Seasonal space heating efficiency)

%

180

Prated at -10°C

kW

57.45

Seasonal space heating eff. class

A+++

A Condition (-7°CDB/-8°CWB)

COPd

4.97

Pdh

kW

57.26

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating)

0.9

COPd

5.49

Pdh

kW

58.99

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating)

0.9

COPd

5.76

Pdh

kW

59.62

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating)

0.9

COPd

6.19

Pdh

kW

60.39

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW

0.0

Tbiv (bivalent temperature)

COPd

5.49

Pdh

kW

58.99

Tbiv

°C

2

Tol (temperature operating limit)

COPd

5.11

Pdh

kW

58.62

TOL

°C

-10.0

WTOL

°C

55.0

Cold climate water outlet 35°C

General

Annual energy consumption

kWh

40,557

Ƞs (Seasonal space heating efficiency)

%

192

Prated at -22°C

kW

57.45

Warm climate water outlet 35°C

General

Annual energy consumption

kWh

9,859

Ƞs (Seasonal space heating efficiency)

%

173

Prated at 2°C

kW

57.45

Power consumption in other than active mode

Crankcase heater mode

PCK

W

0.000

Off mode

POFF

W

0.009

Standby mode

Cooling

PSB

W

0.009

Thermostat-off mode

PTO

Cooling

W

0.540

Power supply

Name

W1

Phase

3~

Frequency

Hz

50

Voltage

V

400

Voltage range

Min.

%

-10

Max.

%

10

Unit

Starting current

Max

A

117.55

Running current

Cooling

Nom.

A

18.69

Max

A

31.31

Max unit current for wires sizing

A

34.44

Compressor

Phase

Voltage

V

Voltage range

Min.

%

Max.

%

Maximum running current

A

Starting method

Direct on line




PDF Data Sheet:





 

Not yet reviewed
Write an online review and share your thoughts with other shoppers!