Daikin Air Conditioning Altherma Air Source Heat Pump

Daikin Altherma EPGA16DV + EABH16D6V Air to Water Heat pump Low Temperature Split 16Kw/55000Btu HO

Daikin Altherma EPGA16DV + EABH16D6V Air to Water Heat pump Low Temperature Split 16Kw/55000Btu HO

£7,910.56 £6,592.13 (ex. VAT)
Stock Status: Sold Out
Sorry, this item is out of stock
Blog
Daikin Altherma EPGA16DV+EABH16D6V Air to Water Heat pump Low Temperature Split 16Kw/55000Btu HO 240V~50Hz - HO-HEATING ONLY 

Available in heating only (EAVH-D) and reversible (EAVX-D) models

This Kit Includes:


 

Part Number

Description             

EPGA14DV+EABH16D6V

+BRC1HH

Size 14Kw Split Heating 1ph HEATING ONLY

EPGA14DV

14 kW outdoor unit R32

EABH16D6V

14kW equivalent indoor wall hung unit with 6kW BUH 

BRC1HHDW/DS/DK + EK2CB07CV3

User Interface Controller + wiring centre box

With a water temperature of 60°C at -10°C, the H-Split is perfect for:

  • New build and renovation projects
  • Combining with underfloor heating, heat pump convectors and radiators

Key Product Features:

  • Modern design to blend in with surroundings
  • Compact dimensions with minimal side clearances
  • Stylish on-board graphic controls with remote access options
  • Setup wizard for rapid commissioning
  • Front access to electrical and hydronic components for ease of installation
  • Integrated back-up heater in 6 or 9kW
  • Combine with Daikin hot water tanks, heat pump convectors or underfloor heating
  • Energy performance, using R32, the heat pump reaches the highest energy performances represented by the energy labels.
  • Higher capacity at low ambient
  • Equipped with a new gas injection compressor designed to operate down to -28°C outside air temperature
  • Significantly improved capacity at low ambient temperatures, with a 35% increase at -7°C compared to its predecessor
  • Low sound mode for more sensitive urban areas, a low sound mode reduces the sound level by -3 dB(A).
  • Wall unit designed for flexibility and ease of installation

Daikin Altherma H-Split operates in a single mode, or combination of modes: Domestic hot water, Heating

New generation of R32 Altherma heat pump units, the first air to water heat pump powered by low global warming potential refrigerant R32 with Bluevolution technology with a A+++ rating. Delivers heating efficiency of a high 5.1 COP at 7-35ºC and a high performance low noise unit. Delivering temperatures of up to 60ºC at high efficiency, for reliable operation even in the coldest weather. Ease of installation with all hydraulic elements included in indoor unit. The refrigerant is charged in the outdoor unit for fast installation. Quick, remote commissioning via controller configuration wizard.  Smart comfort gives the user a stylish interface and precision control via the smartphone app. The unit can be combined with Daikin fan coil units, floor heating applications, low temperature radiators & domestic hot water tank. A remote controller user interface is supplied with the unit kit to control your installation. 

 
Technical Data:

Single Phase EPGA-DV Low Temperature Split (R32) Heat Pump (outdoor):

Outdoor Units

Single Phase

EPGA16DV

Description

16kW, 1-phase, 230V

Trade Unit Price

£3,680.00

Dimensions Height x Width x Depth mm

1440 x 1160 x 380

Weight kg

143

Nominal capacity

  1. (a/b) kW

16.50 / 15.60

  1. (c/d) kW

13.50 / 11.90

Nominal input

  1. (a/b) kW

3.45 / 4.21

  1. (c/d) kW

3.42 / 3.97

Seasonal space heating efficiency*

Space heating (Average climate) 35°C

Class

A+++

Efficiency

182

SCOP

4.61

Space heating (Average climate) 55°C

Class

A++

Efficiency

134

SCOP

3.43

COP Heating (a/b)

4.78 / 3.71

EER Cooling (c/d)

3.94 / 2.99

Operation range

Heating °C

-28 to +35

Cooling °C

+10 to +43

Domestic Hot water °C

-28 to +35

Sound pressure / power level

Heating dBA

52 / 66

Cooling dBA

55 / 68

Refrigerant charge R-32 kg

3.5

  1. Connections (Diameter) inches

1" (Male)

Maximum piping length OU to IU[1] m

10[1]

Power supply

1-phase / 230V / 50Hz

Recommended fuses A

32

Low Temperature H-Split (R32) Heat Pump Indoor Unit:

Indoor Unit (wall hung)

Heating Only

Single Phase

EABH16D6V

Trade Unit Price

£2,152.00

Compatible outdoor unit

EPGA11-16DV

User interface (Must be ordered separately)

BRC1HHD(W/S/K)

Function

Heating Only

Dimensions                                                          H x W x D              mm

840 x 440 x 390

Leaving water temperature range

Heating                 °C

+18 to +65

Cooling                °C

-

Pump   No. of speeds

Inverter controlled

Expansion vessel volume   litres

10

Minimum water volume litres

20

Water connections          Inch

1” (female)

Back-up heater fuse rating

6kW 1ph 230V     A

32

9kW 3ph 400V     A

-

Notes: i) Back-up heaters are three step control, 1 phase 2-4-6 kW and 3 phase 3-6-9 kW

Accessories: 

Accessory Ref

Description

Trade Price

BRC1HHDW

Madoka Heating - White

£84.00

BRC1HHDS

Madoka Heating - Silver

£84.00

BRC1HHDK

Madoka Heating - Black

£84.00

AFVALVE1

Anti-freeze valve for glycol free systems (two required per heat pump)

£91.00

EKPCCAB4

PC cable – to upload field settings from PC to unit

£215.00

EKRSC1

Optional remote temperature sensor for outdoor unit*

£71.00

KRCS01-1

Optional remote temperature sensor for indoor unit*

£54.00

EKRP1HBA

Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation

£123.00

K.FF600ASN

Pair of flexi-feet for mounting outdoor unit

£55.00

K.HOSE750

Pair of flexible hoses (Length 750mm, 19mm tough PVC coated insulation, 1" FBSP x 28mm compression)

£80.00

K.HOSE750EL

Pair of flexible hoses with elbow (Length 750mm, 19mm tough PVC coated insulation, 1" FBSP x 28mm compression)

£114.00

BRP069A62

Smart Comfort Controller

£143.00

EKUMBPART

3rd party tank connection kit - Dry pocket sensor

£210.00

K.ELECMETV

Electric meter for domestic RHI - Single-phase (Metering for performance compliant)

MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump

£129.00

K.ELECMETW

Electric meter for domestic RHI - Three-phase (Metering for performance compliant)

MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump

£230.00


 




PDF Data:


 


 

Not yet reviewed
Write an online review and share your thoughts with other shoppers!
Be the first to review this product