Daikin Altherma EPGA16DV+EABH16D6V Air to Water Heat pump Low Temperature Split 16Kw/55000Btu HO 240V~50Hz - HO-HEATING ONLY
Available in heating only (EAVH-D) and reversible (EAVX-D) models
This Kit Includes:
Part Number
|
Description
|
EPGA14DV+EABH16D6V
+BRC1HH
|
Size 14Kw Split Heating 1ph HEATING ONLY
|
EPGA14DV
|
14 kW outdoor unit R32
|
EABH16D6V
|
14kW equivalent indoor wall hung unit with 6kW BUH
|
BRC1HHDW/DS/DK + EK2CB07CV3
|
User Interface Controller + wiring centre box
|
With a water temperature of 60°C at -10°C, the H-Split is perfect for:
- New build and renovation projects
- Combining with underfloor heating, heat pump convectors and radiators
Key Product Features:
- Modern design to blend in with surroundings
- Compact dimensions with minimal side clearances
- Stylish on-board graphic controls with remote access options
- Setup wizard for rapid commissioning
- Front access to electrical and hydronic components for ease of installation
- Integrated back-up heater in 6 or 9kW
- Combine with Daikin hot water tanks, heat pump convectors or underfloor heating
- Energy performance, using R32, the heat pump reaches the highest energy performances represented by the energy labels.
- Higher capacity at low ambient
- Equipped with a new gas injection compressor designed to operate down to -28°C outside air temperature
- Significantly improved capacity at low ambient temperatures, with a 35% increase at -7°C compared to its predecessor
- Low sound mode for more sensitive urban areas, a low sound mode reduces the sound level by -3 dB(A).
- Wall unit designed for flexibility and ease of installation
Daikin Altherma H-Split operates in a single mode, or combination of modes: Domestic hot water, Heating
New generation of R32 Altherma heat pump units, the first air to water heat pump powered by low global warming potential refrigerant R32 with Bluevolution technology with a A+++ rating. Delivers heating efficiency of a high 5.1 COP at 7-35ºC and a high performance low noise unit. Delivering temperatures of up to 60ºC at high efficiency, for reliable operation even in the coldest weather. Ease of installation with all hydraulic elements included in indoor unit. The refrigerant is charged in the outdoor unit for fast installation. Quick, remote commissioning via controller configuration wizard. Smart comfort gives the user a stylish interface and precision control via the smartphone app. The unit can be combined with Daikin fan coil units, floor heating applications, low temperature radiators & domestic hot water tank. A remote controller user interface is supplied with the unit kit to control your installation.
Technical Data:
Single Phase EPGA-DV Low Temperature Split (R32) Heat Pump (outdoor):
Outdoor Units
|
Single Phase
|
EPGA16DV
|
Description
|
16kW, 1-phase, 230V
|
Trade Unit Price
|
£3,680.00
|
Dimensions Height x Width x Depth mm
|
1440 x 1160 x 380
|
Weight kg
|
143
|
Nominal capacity
|
- (a/b) kW
|
16.50 / 15.60
|
- (c/d) kW
|
13.50 / 11.90
|
Nominal input
|
- (a/b) kW
|
3.45 / 4.21
|
- (c/d) kW
|
3.42 / 3.97
|
Seasonal space heating efficiency*
|
Space heating (Average climate) 35°C
|
Class
|
A+++
|
Efficiency
|
182
|
SCOP
|
4.61
|
Space heating (Average climate) 55°C
|
Class
|
A++
|
Efficiency
|
134
|
SCOP
|
3.43
|
COP Heating (a/b)
|
4.78 / 3.71
|
EER Cooling (c/d)
|
3.94 / 2.99
|
Operation range
|
Heating °C
|
-28 to +35
|
Cooling °C
|
+10 to +43
|
Domestic Hot water °C
|
-28 to +35
|
Sound pressure / power level
|
Heating dBA
|
52 / 66
|
Cooling dBA
|
55 / 68
|
Refrigerant charge R-32 kg
|
3.5
|
- Connections (Diameter) inches
|
1" (Male)
|
Maximum piping length OU to IU[1] m
|
10[1]
|
Power supply
|
1-phase / 230V / 50Hz
|
Recommended fuses A
|
32
|
Low Temperature H-Split (R32) Heat Pump Indoor Unit:
Indoor Unit (wall hung)
|
Heating Only
|
Single Phase
|
EABH16D6V
|
Trade Unit Price
|
£2,152.00
|
Compatible outdoor unit
|
EPGA11-16DV
|
User interface (Must be ordered separately)
|
BRC1HHD(W/S/K)
|
Function
|
Heating Only
|
Dimensions H x W x D mm
|
840 x 440 x 390
|
Leaving water temperature range
|
Heating °C
|
+18 to +65
|
Cooling °C
|
-
|
Pump No. of speeds
|
Inverter controlled
|
Expansion vessel volume litres
|
10
|
Minimum water volume litres
|
20
|
Water connections Inch
|
1” (female)
|
Back-up heater fuse rating
|
6kW 1ph 230V A
|
32
|
9kW 3ph 400V A
|
-
|
Notes: i) Back-up heaters are three step control, 1 phase 2-4-6 kW and 3 phase 3-6-9 kW
Accessories:
Accessory Ref
|
Description
|
Trade Price
|
BRC1HHDW
|
Madoka Heating - White
|
£84.00
|
BRC1HHDS
|
Madoka Heating - Silver
|
£84.00
|
BRC1HHDK
|
Madoka Heating - Black
|
£84.00
|
AFVALVE1
|
Anti-freeze valve for glycol free systems (two required per heat pump)
|
£91.00
|
EKPCCAB4
|
PC cable – to upload field settings from PC to unit
|
£215.00
|
EKRSC1
|
Optional remote temperature sensor for outdoor unit*
|
£71.00
|
KRCS01-1
|
Optional remote temperature sensor for indoor unit*
|
£54.00
|
EKRP1HBA
|
Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation
|
£123.00
|
K.FF600ASN
|
Pair of flexi-feet for mounting outdoor unit
|
£55.00
|
K.HOSE750
|
Pair of flexible hoses (Length 750mm, 19mm tough PVC coated insulation, 1" FBSP x 28mm compression)
|
£80.00
|
K.HOSE750EL
|
Pair of flexible hoses with elbow (Length 750mm, 19mm tough PVC coated insulation, 1" FBSP x 28mm compression)
|
£114.00
|
BRP069A62
|
Smart Comfort Controller
|
£143.00
|
EKUMBPART
|
3rd party tank connection kit - Dry pocket sensor
|
£210.00
|
K.ELECMETV
|
Electric meter for domestic RHI - Single-phase (Metering for performance compliant)
MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump
|
£129.00
|
K.ELECMETW
|
Electric meter for domestic RHI - Three-phase (Metering for performance compliant)
MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump
|
£230.00
|
PDF Data: