Daikin Air Conditioning RXM20R-FTXM20R Wall Mounted 2.0Kw/7000Btu Inverter Heat Pump R32 A+++ Wi-Fi

£898.45 £748.71 (ex. VAT)
Stock Status: In Stock
Blog

Daikin Air Conditioning RXM20R - FTXM20R Wall Mounted 2.0Kw/7000Btu Inverter Heat Pump R32 A+++ Wi-Fi embedded Wi-Fi 220-240V~50Hz

This Is a Complete Kit which Includes:

1 x Daikin Air Conditioning FTXM20R Wall Mounted 2.0Kw/7000Btu Heat Pump R32 A+++ With Wi-Fi fitted as standard

1 x Daikin Air Conditioning RXM20R Outdoor Unit 2.0Kw/7000Btu Inverter Heat Pump R32 A+++ 240V~50Hz

1 x Daikin Air Conditioning ARC466A67 Ir remote control



   

High Seasonal Efficiency A+++ Rated
 

The new FTXM range is equipped with an advanced heating function to provide ideal comfort. When the Heat Boost mode is activated, the space is warmed up rapidly as the set temperature is reached 14% faster when compared with common air conditioners. Suitable for bedrooms, living rooms or small offices, the FTXM range is equipped with an infra-red remote control with a 7-day timer. The timer allows you to programme a 7-day schedule with 4 different actions per day. Alternatively, the FTXM can be controlled via smart phone or tablet using the “Residential Controller App”, Alexa or Google Home. The indoor unit is easily connected using the integrated WLAN PCB board. All units are fitted with 2-area Intelligent Eye sensors, which keep the room comfortable while ensuring running costs are kept to a minimum. About the Intelligent eye: If the sensor detects the room is empty, it will switch to economy mode to save energy then restarts when someone re-enters. When people are detected in the room the sensor will direct air-flow away from them. All units in the FTXM range are fitted with a Titanium apatite deodorising filter which eliminates odours from e.g. tobacco and pets smells. The Flash Streamer, which breaks down allergens such as pollen and fungal spores, provides better and cleaner air. Please note the Flash Streamer technology has not been certified for medical purposes.


 

Key Product Features:

Features

Benefits

Heat Boost Mode

Compressor frequency is adjusted for a quick and comfortable heating start up so set temperature can be reached faster.

Flash Streamer

Breaks down allergens such as pollen and fungal spores and removes odours providing better, cleaner air. The Flash Streamer is not meant to be used for medical purposes.

Intelligent Eye Sensor

Reduced running costs by switching to economy mode when the room is empty.

7 day timer

Set a full week of on and off-timings, allowing differences in schedule for week and weekends

Very low noise level

Quiet operation means that the FTXM series is unobtrusive when operating.

Automatic airflow adjustment

Can improve comfort levels as the unit will automatically match fan-speed according to room temperature.

Technical Data:

Indoor Units

FTXM20R

Capacity

Nominal Cooling                       kW

2.0

Nominal Heating                       kW

2.5

Seasonal Efficiency (EN14825) COOLING

Energy Label

A+++

Pdesign      kW

2.0

SEER

8.65

Annual Energy Consumption kWh

81

Seasonal Efficiency (EN14825) HEATING

Energy Label

A+++

Pdesign       kW

2.3

SCOP

5.10

Annual Energy

Consumption kWh

632

Nominal Efficiency                 EER/COP

4.57 / 5.00

Air Flow Rate (Cooling)   High / Nom / Low / Silent  m3/sec

0.185 / - / 0.100 / 0.073

Dimensions

Height     mm

295

Width      mm

778

Depth            mm

272

Weight            kg

12

Sound Pressure (Cooling)       High / Nom / Low / Silent          dBA

41 /19

Sound Pressure (Heating)     High / Nom / Low / Silent        dBA

39  / 20

Sound Power (Cooling)        dBA

57

Outdoor Units

RXM20R

Dimensions                          Height x Width x Depth          mm

550 x 765 x 285

Weight         kg

32

Electrical Details

Power Supply

1ph

Running Current - Cooling     A

2.10

Max Fuse Size                            A

10

Interconnection Wiring         Core / Cable size

3+E  /  1.5

Piping ConnectionS Liquid / Gas     inches (mm)

1/4 (6.35) / 3/8 (9.5)

Pipe-work

Maximum Length                      m

20

Maximum Vertical Rise            m

20

Pre-charged to                            m

10

Additional Charge                   g/m

20

Holding Charge                        kg

0.76

Sound Pressure (Cooling)     Nominal                                       dBA

46

Sound Pressure (Heating)     Nominal                                      dBA

47

Sound Power (Cooling)                                                                dBA

59

Operating Range (Cooling)   Min / Max                                   °CDB

-10 / 50

Operating Range (Heating)  Min / Max                                  °CWB

-20 / 24

Accessories:

Accessory Ref

Description

BRC073

Wired remote control - connection cable required

BRP069B45

Wifi adaptor for connection to on-line controller

BRCW901A03

3m extension cord required for wired remote controller BRC073

BRCW901A08

8m extension cord required for wired remote controller BRC073

K.CWB90-2

Wall bracket (90kg, 500mm support arm)

K.DT1

Condensate drip tray for use with Split ODU - tray width 800mm

K.CGS

Condensing unit guard (750 x 1050 x 460)

K.CGM

Condensing unit guard (1150 x 1150 x 650)

KLIC-DDV3

KNX interface for Split type systems

KRP413A1S

Adaptor PCB for remote on/off control - constant/ pulse contact

KRP928A2S

Adaptor PCB for interface to Daikin centralised control systems

RTD-RA

Adaptor PCB for Modbus connection and/or extended system functions



These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.

 
 

Not yet reviewed
Write an online review and share your thoughts with other shoppers!
Be the first to review this product