Daikin Air conditioning Multi 1 x 2MXM50A 2 x FTXP35M9 3.5Kw Wall Mounted Heat Pump R32 A+ 240V~50Hz A+ Rated energy product

This Kit Includes:
1 x 2MXM50A 5kw / 18000Btu Inverter Heat Pump Condensing unit 2 port 240V 50Hz
1 x FTXP35M9 3.5kw / 12000 Btu Heat pump wall Indoor Unit
2 x Remote controllers ARC480A53

The variable capacity R32 multi systems are ideal for light commercial and residential applications, having the highest SCoP and low start currents, ideal where there is limited power supply. The Inverter outdoor units are suitable for 2 connected indoor units, depending on the model. Each indoor unit is connected directly by a pair of small diameter refrigerant pipes to the outdoor unit.
There are no branch joints involved. All connected indoor units operate in the same mode, i.e. either all Heating, or all Cooling. There are many permutations of connectible indoor units to each outdoor unit. These are listed below. The cooling and heating data is based on all connected units operational at the same time at full load. In practise the load in each room is unlikely to be at 100% continuously, so the available spare capacity is then shared to other units accordingly. Daikin air conditioning has been manufacturing multi systems for residential applications for many years. The latest state-of-the-art Inverter technology is now applied to the range, delivering exceptionally high efficiency, as well as variable individual unit control for stable and comfortable conditions.
Product Key Feature's:
• High sCoP
• 1 Outdoor unit saving space
• Energy saving inverter
• New advanced technology control
• Infra-red controller with wall mounting bracket
• Reduced height slim construction
• Pipe runs up to 30 metres total
• Low noise – 19dBA on smaller models
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 20 metres pipe length
OUTDOOR UNIT:
| Compressor |
Type |
Hermetically sealed swing compressor |
|
| Dimensions |
Unit |
Depth |
350 |
mm |
|
|
Height |
552 |
mm |
|
|
Width |
852 |
mm |
| Operation range |
Cooling |
Ambient |
Min. |
-10 |
°CDB |
|
|
|
Max. |
46 |
°CDB |
| Piping connections |
Additional refrigerant charge |
0.02 (for piping length exceeding 20m) |
kg/m |
|
Level difference |
IU |
OU |
Max. |
15 |
m |
|
|
|
IU |
Max. |
7.5 |
m |
|
Total piping length |
System |
Actual |
30 |
m |
| Power supply |
Frequency |
50 |
Hz |
|
Phase |
1~ |
|
|
Voltage |
220-240 |
V |
| Refrigerant |
Charge |
1.15 |
kg |
|
GWP |
675 |
|
|
Type |
R-32 |
|
| Sound pressure level |
Cooling |
Nom. |
48 |
dBA |
|
Heating |
Nom. |
50 |
dBA |
| Weight |
Unit |
41 |
kg |
INDOOR UNITS:
| Casing |
Colour |
White |
|
| Control systems |
Infrared remote control |
ARC480A53 |
|
|
Wired remote control |
BRC944B2 BRC073A1 |
|
| Dimensions |
Unit |
Depth |
225 |
mm |
|
|
Height |
286 |
mm |
|
|
Width |
770 |
mm |
| Fan |
Air flow rate |
Cooling |
High |
11.5 |
m³/min |
|
|
|
Medium |
8.3 |
m³/min |
|
|
|
Low |
6.3 |
m³/min |
|
|
|
Silent operation |
4.5 |
m³/min |
|
|
Heating |
High |
11.5 |
m³/min |
|
|
|
Medium |
9.0 |
m³/min |
|
|
|
Low |
7.0 |
m³/min |
|
|
|
Silent operation |
5.3 |
m³/min |
| Piping connections |
Drain |
18 |
|
|
Gas |
OD |
9.50 |
mm |
|
Liquid |
OD |
6.35 |
mm |
| Power input |
Cooling |
Nom. |
0.032 |
kW |
| Power supply |
Frequency |
50 |
Hz |
|
Phase |
1~ |
|
|
Voltage |
220-240 |
V |
| Sound power level |
Cooling |
58 |
dBA |
|
Heating |
Heating |
58 |
dBA |
| Sound pressure level |
Cooling |
High |
43 |
dBA |
|
|
Low |
27 |
dBA |
|
|
Medium |
34 |
dBA |
|
|
Silent operation |
20 |
dBA |
|
Heating |
High |
40 |
dBA |
|
|
Low |
29 |
dBA |
|
|
Medium |
35 |
dBA |
|
|
Silent operation |
21 |
dBA |
| Weight |
Unit |
9.00 |
kg |
PDF Data:

Accessories:
|
Accessory Ref
|
Description
|
|
BRC073
|
Wired remote control - connection cable required
|
|
BRP069B45
|
Wi-fi adaptor for connection to on-line controller
|
|
BRCW901A03
|
3m extension cord required for wired remote controller BRC073
|
|
BRCW901A08
|
8m extension cord required for wired remote controller BRC073
|
|
K.CWB90-2
|
Wall bracket (90kg, 500mm support arm)
|
|
K.DT1
|
Condensate drip tray for use with Split ODU - tray width 800mm
|
|
K.CGS
|
Condensing unit guard (750 x 1050 x 460)
|
|
K.CGM
|
Condensing unit guard (1150 x 1150 x 650)
|
|
KLIC-DDV3
|
KNX interface for Split type systems
|
|
KRP413A1S
|
Adaptor PCB for remote on/off control - constant/ pulse contact
|
|
KRP928A2S
|
Adaptor PCB for interface to Daikin centralised control systems
|
|
RTD-RA
|
Adaptor PCB for Modbus connection and/or extended system functions
|
These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.