Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Daikin Air Conditioning Roundflow Cassette Inverter Heat Pump FCAG A++

Daikin Air Conditioning FCAG60B+RXM60N9 Round-flow Cassette 6Kw/19000Btu R32 A++ 240V~50Hz

Daikin Air Conditioning FCAG60B+RXM60N9 Round-flow Cassette 6Kw/19000Btu R32 A++ 240V~50Hz

£2,198.75 £1,832.29 (ex. VAT)
Stock Status: In Stock
Blog

Daikin Air Conditioning FCAG60B+RXM60N9 Round-flow Cassette 6Kw/19000Btu R32 A++ 240V~50Hz.

A++ rated energy product


Includes:

1 x Daikin Air Conditioning FCAG60B Roundflow Cassette R32
1 x Daikin Air Conditioning RXM60N9 R32 outdoor unit
1 x Standard BRC Daikin hard wired controller




Daikin air conditioning's unique 360° Roundflow FCAG-B cassette range has a ultra slim casing structure and is designed for restricted space suspended ceilings in residential, office and retail applications. The 360° operation ensures even distribution of temperatures and airflow with no dead spots in the room. The vertical auto swing system automatically cycles the outflow Louvre's up and down, distributing the air and temperature evenly throughout the room. An optional presence sensor saves you up to 27% more in energy use and allows the system to dynamically respond to room occupancy. If the room is empty, air conditioning can be automatically switched off. When the room is occupied, air flow is directed away from occupants for draught-free comfort.  

​Daikin air conditioning's Round-flow cassette air conditioners are of a low profile design (204mm) for easy installation into and plastered ceiling. Daikin's cassette range lead the industry with their energy savings, low sound levels  and wide model range. The Round-flow indoor units are extremely quiet in operation, the sound levels are as low as 28 dB. The filter is able to trap microscopic particles, to decompose odours, and even to remove bacteria and to deactivate viruses. The filter lasts for 3 years without replacement if washed about  around 6 months.

The Round-flow cassette and condenser can be used as a cost effective way to replace old equipment as they are able to use existing R22, R410a and R407C pipe-work. FCAG-B are listed on the Energy Technology List (ETL) – the definitive list of products that qualify for Enhanced Capital Allowance (ECA). A Presence sensor control's the temperature set point based on occupancy and can reduce running costs by up to 27% over a 3 hour period. The remote controller gives access to a range of energy saving settings, allowing control over set-point ranges, fan speed and other day-to-day use of controls. The controller also gives a kWh indication of the power consumed by the cassette and outdoor unit so you can monitor your energy usage.



Product Key Feature's:


• High SCoP, up to record 4.10
• High Air movement volume
• Fixed wall mounted controller
• Slim construction
• Pipe runs up to 50 meters
• Low noise levels
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for
up to 30 metres pipe length

 


Product Technical Data:

FCAG60B / RXM60N9

Indoor unit

FCAG60BVEB

Outdoor unit

RXM60N2V1B9

Cooling capacity

Nom.

kW

5.70

Nom.

Btu/h

19,400

Nom.

kcal/h

4,901

Heating capacity

Nom.

kW

7.00

Nom.

Btu/h

23,900

Nom.

kcal/h

6,019

Power input

Cooling

Nom.

kW

1.72

Heating

Nom.

kW

2.07

Nominal efficiency

EER

3.31

COP

3.38

Annual energy consumption

kWh

861

Energy labeling Directive

Cooling

A

Heating

C

Space cooling

Energy efficiency class

A++

Capacity

Pdesign

kW

5.70

SEER

6.40

Annual energy consumption

kWh/a

312

A Condition (35°C - 27/19)

Pdc

kW

5.68

EERd

3.31

Power input

kW

1.72

B Condition (30°C - 27/19)

Pdc

kW

4.16

EERd

4.67

Power input

kW

0.89

C Condition (25°C - 27/19)

Pdc

kW

2.70

EERd

7.87

Power input

kW

0.34

D Condition (20°C - 27/19)

Pdc

kW

1.62

EERd

12.03

Power input

kW

0.13

Space heating (Average climate)

Energy efficiency class

A+

Capacity

Pdesign

kW

4.71

SCOP/A

4.20

SCOPnet/A

4.22

Pdh Heating capacity at -10°

kW

4.12

Annual energy consumption

kWh/a

1,569

Required back up heating cap at design conditions

kW

0.59

TOL

Tol (temperature operating limit)

°C

-15

Pdh (declared heating cap)

kW

4.04

COPd (declared COP)

2.08

Power input

kW

1.94

TBivalent

Tbiv (bivalent temperature)

°C

-7

Pdh (declared heating cap)

kW

4.17

COPd (declared COP)

2.56

Power input

kW

1.63

A Condition (-7°C)

Pdh (declared heating cap)

kW

4.17

COPd (declared COP)

2.56

Power input

kW

1.63

B Condition (2°C)

Pdh (declared heating cap)

kW

2.53

COPd (declared COP)

4.30

Power input

kW

0.59

C Condition (7°C)

Pdh (declared heating cap)

kW

1.64

COPd (declared COP)

5.28

Power input

kW

0.31

D Condition (12°C)

Pdh (declared heating cap)

kW

1.46

COPd (declared COP)

6.51

Power input

kW

0.22

Space heating (Warm climate)

Energy efficiency class

A+++

Capacity

Pdesignh

kW

2.53

SCOP

5.36

SCOPnet

5.41

Annual energy consumption

kWh/a

661

Required back up heating cap at design conditions

kW

0.00

TOL

Tol (temperature operating limit)

°C

-15

Pdh (declared heating cap)

kW

4.04

COPd (declared COP)

2.08

Power input

kW

1.94

TBivalent

Tbiv (bivalent temperature)

°C

2

Pdh (declared heating cap)

kW

2.53

COPd (declared COP)

4.30

Power input

kW

0.59

B Condition (2°C)

Pdh (declared heating cap)

kW

2.53

COPd (declared COP)

4.30

Power input

kW

0.59

C Condition (7°C)

Pdh (declared heating cap)

kW

1.64

COPd (declared COP)

5.28

Power input

kW

0.31

D Condition (12°C)

Pdh (declared heating cap)

kW

1.46

COPd (declared COP)

6.51

Power input

kW

0.22

Power consumption in other than active mode

Crankcase heater mode

Cooling

PCK

kW

0.000

Heating

PCK

kW

0.000

Off mode

Cooling

POFF

kW

0.007

Heating

POFF

kW

0.007

Standby mode

Cooling

PSB

kW

0.007

Heating

PSB

kW

0.007

Thermostat-off mode

Cooling

PTO

kW

0.007

Heating

PTO

kW

0.007

Cooling

Cdc (Degradation cooling)

0.25

Heating

Cdh (Degradation heating)

0.25

Cooling function included

Yes

Heating function included

Yes

Average climate included

Yes

Cold season included

No

Warm season included

Yes

Eurovent

Sound power level outdoor

Cooling

Nom.

dBA

63

Sound power level indoor

Cooling

Nom.

dBA

51

Piping length

Cooling

Measuring condition

m

5.00

Notes

(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.

(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.

(3) - See separate drawing for operation range

(4) - See separate drawing for electrical data




   

Accessories:

BYCQ140E     Decoration panel - White (Included as standard)
YCQ140EB         Decoration panel - Black
BRP069B82        Wifi adaptor for connection to on-line controller
BRC1H519W7      New - wired touch screen remote controller - White (Included asstandard)
BRC1H519S7    New - wired touch screen remote controller - Silver
BRC1H519K7    New - wired touch screen remote controller - Black
BRC7FA532F     Wireless remote controller
BRYQ140B      Integral PIR sensor for roundflow decoration panel (for white panel)
BRYQ140BB      Integral PIR sensor for roundflow decoration panel (for black panel)
BYCQ140EGF      Auto Cleaning Deco Panel - White
BYCQ140EGFB      Auto Cleaning Deco Panel - Black
BYCQ140EW    Decoration Panel - Full White
EWHAR1        Extension wire - Required if Wifi Adaptor and Auto Cleaning panel are installed together
K.CGL      Condensing unit guard size 100-140
K.CGM       Condensing unit guard size 42-71

K.CWB140-2                     Condensing unit bracket - size 100 to 140
K.CWB90-2                    Condensing unit bracket - up to size 71, max weight 90kg of
ODU K.DT1                       Condensate drip tray for use with K.CWB90-2
K.DT2                                 Condensate drip tray for use with K.CWB140-2
K.RSS                                  Wireless room mounted temperature sensor and receiver 
KDBHQ55B140                 Sealing member for air discharge outlet
KDDP55C160-1        Fresh air intake kit for up to 20% fresh air (Part 1)
KDDQ55B140-2         Fresh air intake kit for up to 20% fresh air (Part 2)
KLIC-DI                               KNX Interface for Sky Air and VRV systems
KRCS01-4                          Remote room mounted temperature sensor
KRP4A53 and UK.FB2     Unit/group adaptor PCB for remote on/off, status indication and temperature setting
RS-SE                              Service and configuration tool for K.RSS
RTD-10 and UK.FB2      Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
RTD-20 and UK.FB2        Energy control PCB for Sky Air and VRV RTD-NET
UK.FB2         Modbus interface PCB for Sky Air and VRV



 

PDF Data:
 




These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.

Not yet reviewed
Write an online review and share your thoughts with other shoppers!