Daikin Air Conditioning FCAG140B+AZAS140MV1 Round-flow Cassette 14Kw/48000Btu R32 A+ 240V/415V~50Hz
A+ rated energy product
Includes:
1 x Daikin Air Conditioning FCAG140B Round-flow Cassette R32
1 x Daikin Air Conditioning AZAS140MV1 Active R32 outdoor unit
1 x Standard BRC Daikin hard wired controller

Daikin air conditioning's unique 360° Roundflow FCAG-A cassette range has a ultra slim casing structure and is designed for restricted space suspended ceilings in residential, office and retail applications. The 360° operation ensures even distribution of temperatures and airflow with no dead spots in the room. The vertical auto swing system automatically cycles the outflow louvers up and down, distributing the air and temperature evenly throughout the room. An optional presence sensor saves you up to 27% more in energy use and allows the system to dynamically respond to room occupancy. If the room is empty, air conditioning can be automatically switched off. When the room is occupied, air flow is directed away from occupants for draught-free comfort.
Daikin air conditioning's Round-flow cassette air conditioners are of a low profile design (204mm) for easy installation into and plastered ceiling. Daikin's cassette range lead the industry with their energy savings, low sound levels and wide model range. The Round-flow indoor units are extremely quiet in operation, the sound levels are as low as 28 dB. The filter is able to trap microscopic particles, to decompose odours, and even to remove bacteria and to deactivate viruses. The filter lasts for 3 years without replacement if washed about around 6 months.
The Round-flow cassette and RXS condenser can be used as a cost effective way to replace old equipment as they are able to use existing R22, R410A and R407C pipe-work. A Presence sensor controls the temperature set point based on occupancy and can reduce running costs by up to 27% over a 3 hour period. The remote controller gives access to a range of energy saving settings, allowing control over set-point ranges, fan speed and other day-to-day use of controls. The controller also gives a kWh indication of the power consumed by the cassette and outdoor unit so you can monitor your energy usage.
Product Key Feature's:
• High SCoP, up to record 4.10
• High Air movement volume
• Fixed wall mounted controller
• Slim construction
• Pipe runs up to 50 meters
• Low noise levels
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for
up to 30 metres pipe length
Product Technical Data:
Indoor Units
|
Single Phase
|
3 Phase
|
FCAG140B
|
FCAG140B
|
Capacity
|
UK Total Cooling kW
|
14.90
|
14.90
|
UK Sensible Cooling kW
|
10.25
|
10.25
|
Nominal Cooling kW
|
13.4
|
13.4
|
Nominal Heating kW
|
15.5
|
15.5
|
Seasonal Efficiency (EN14825) COOLING
|
Energy Label
|
-
|
-
|
Pdesign kW
|
13.0
|
13.0
|
SEER
|
6.00
|
6.00
|
Annual Energy Consumption kWh
|
1300
|
1300
|
Seasonal Efficiency (EN14825) HEATING
|
Energy Label
|
-
|
-
|
Pdesign kW
|
7.8
|
7.8
|
SCOP
|
4.31
|
4.31
|
Annual Energy Consumption kWh
|
2534
|
2534
|
Nominal Efficiency EER/COP
|
2.63/3.73
|
2.63/3.73
|
Air Flow Rate (Cooling) High / Nom / Low m3/sec
|
0.433/0.320/0.206
|
0.433/0.320/0.206
|
Dimensions
(with Decoration Panel)
|
Height mm
|
246 (306)
|
246 (306)
|
Width mm
|
840 (950)
|
840 (950)
|
Depth mm
|
840 (950)
|
840 (950)
|
Weight (with Decoration Panel) kg
|
24 (29.4)
|
24 (29.4)
|
Sound Pressure (Cooling) High / Nom / Low dBA
|
41/35/29
|
41/35/29
|
Sound Pressure (Heating) High / Nom / Low dBA
|
41/35/29
|
41/35/29
|
Sound Power (Cooling) dBA
|
58
|
58
|
Outdoor Units
|
AZAS140MV1
|
AZAS140MY1
|
Dimensions Height x Width x Depth mm
|
990 x 940 x 320
|
990 x 940 x 320
|
Weight kg
|
78
|
77
|
Electrical Details
|
Power Supply
|
1ph
|
3ph
|
Maximum Input Current (MCA) A
|
27
|
14.6
|
Max Fuse Size A
|
32
|
16
|
Interconnection Wiring Core / Cable Size
|
3+E / 1.5
|
3+E / 1.5
|
Piping Connections Liquid / Gas inches (mm)
|
3/8 (9.5) /
5/8 (15.9)
|
3/8 (9.5) /
5/8 (15.9)
|
Pipework
|
Maximum Length m
|
30
|
30
|
Maximum Vertical Rise m
|
30
|
30
|
Precharged to m
|
30
|
30
|
Additional charge g/m
|
Refer to Installation Manual
|
Refer to Installation Manual
|
Holding charge kg
|
2.90
|
2.90
|
Sound Pressure (Cooling) Nom / Night Quiet dBA
|
54/44
|
54/44
|
Sound Pressure (Heating) Nom / Night Quiet dBA
|
57/44
|
57/44
|
Sound Power (Cooling) dBA
|
73
|
73
|
Operating Range (Cooling) Min / Max °CDB
|
-5/46
|
-5/46
|
Operating Range (Heating) Min / Max °CWB
|
-15/15.5
|
-15/15.5
|
Air Flow Rate (Cooling) Nominal m3/sec
|
1.266
|
1.266
|
Accessories:
BYCQ140E Decoration panel - White (Included as standard)
YCQ140EB Decoration panel - Black
BRP069B82 Wifi adaptor for connection to on-line controller
BRC1H519W7 New - wired touch screen remote controller - White (Included asstandard)
BRC1H519S7 New - wired touch screen remote controller - Silver
BRC1H519K7 New - wired touch screen remote controller - Black
BRC7FA532F Wireless remote controller
BRYQ140B Integral PIR sensor for roundflow decoration panel (for white panel)
BRYQ140BB Integral PIR sensor for roundflow decoration panel (for black panel)
BYCQ140EGF Auto Cleaning Deco Panel - White
BYCQ140EGFB Auto Cleaning Deco Panel - Black
BYCQ140EW Decoration Panel - Full White
EWHAR1 Extension wire - Required if Wifi Adaptor and Auto Cleaning panel are installed together
K.CGL Condensing unit guard size 100-140
K.CGM Condensing unit guard size 42-71
K.CWB140-2 Condensing unit bracket - size 100 to 140
K.CWB90-2 Condensing unit bracket - up to size 71, max weight 90kg of
ODU K.DT1 Condensate drip tray for use with K.CWB90-2
K.DT2 Condensate drip tray for use with K.CWB140-2
K.RSS Wireless room mounted temperature sensor and receiver
KDBHQ55B140 Sealing member for air discharge outlet
KDDP55C160-1 Fresh air intake kit for up to 20% fresh air (Part 1)
KDDQ55B140-2 Fresh air intake kit for up to 20% fresh air (Part 2)
KLIC-DI KNX Interface for Sky Air and VRV systems
KRCS01-4 Remote room mounted temperature sensor
KRP4A53 and UK.FB2 Unit/group adaptor PCB for remote on/off, status indication and temperature setting
RS-SE Service and configuration tool for K.RSS
RTD-10 and UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
RTD-20 and UK.FB2 Energy control PCB for Sky Air and VRV RTD-NET
UK.FB2 Modbus interface PCB for Sky Air and VRV
PDF Data:

These air conditioning units must be installed by an F-Gas qualified engineer. We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.