Air Conditioning Installation Manual

All In One Installation Manual

Inverters

Mitsubishi Electric Super High COP Inverter Heat-pump Air Conditioning unit

Portable Server Room Air Conditioning Unit

Pro Audio Equipment

Worcester Hot Water SolarPanel Collector Roof Installation Package

Wind Turbine Kits

Mitsubishi SRK20ZIX AIR TO AIR Heat pump with 5.45 C.O.P

Air Conditioning Information

ECA Capital Allowance for business

Special Offers

Daikin Wall Air Conditioning

Solar PV Panels

Wind Turbine

Air Source Heat-pump heating systems

Wall Air conditioning

Mitsubishi Heavy Industries Air to water heat pump

The New LG Air to water heat pump

Mitsubishi Heavy Industries Air conditioning

Mitsubishi Electric Air conditioning

The new Mitsubishi SRF HYPER Inverter Floor Air Conditioning

Ice makers

Self Install / DIY Air Conditioning

Portable Air Conditioning

Conservatory Air Conditioning

Hailea Water-Chiller HC150A 165 Watt / 150 Litre Cooling Capacity

Dehumidifiers

Portable Air Conditioning

Heat Screen Air Curtain RM125-12-D/Y-A (7.2kw/25000Btu) 1200mm

Conservatory Air Conditioning

EFOY Fuel Cell Generator

Danfoss Compressor

L'Unite Compressor

L'Unit Hermetique Condensing Units

Tecumseh Compressor

LG Air Conditioning

Aspera Compressor

Copeland Compressor

Portable Air Conditioner Midear MPF-12CEN2 (3.5 kW / 12000 Btu) SPECIAL OFFER

Air Conditioning

AGM Batteries

Gel Batteries

Panasonic Aquarea Air to Water Heat Pump Split Systems

Our Price: £3,329.10

Heating only 1 phase

Heating only 3 phase

Heating and Cooling 1 phase

Heating and Cooling 3 phase
Panasonic Aquarea Air to Water Heat Pump Split Systems
Panasonic Aquarea Air to Water Heat Pump Split Systems
Panasonic Aquarea Air to Water Heat Pump Split Systems
Panasonic Aquarea Air to Water Heat Pump Split Systems
Description

Panasonic Aquarea Air to Water Heat Pumps

Positioned as a “green” heating and air-conditioning system, Panasonic’s Aquarea air-to-water heat pump range is part of a new generation of heating and air-conditioning systems designed to heat or cool the home and to produce hot water.

The Aquarea range is available in three versions:
Standard heat pump
High Temperature heat pump
T-CAP (Total Capacity) heat pump

The Aquarea product line includes a wide range from 7 to 16 kW, single and three-phase & stand-alone and split-units. This high-efficiency heat pump operates at outside temperatures as low as –20ºC, and also provides cooling in summer.

Panasonic’s Aquarea heat pump provides savings of up to 78% on heating expenses compared with electrical heaters. For example, Aquarea’s 7 kW system has a COP of 4.40 which means that for every kW of electricity consumed, it returns 4.40 kW of energy, i.e. 3.40 kW more than a conventional electrical heating system which has a maximum COP of 1. This is equivalent to savings of 78%.

 
The split system


This is formed by an outdoor unit and a hydraulic module, normally located in the utility room or garage. This configuration requires refrigerant pipes between the two units but is easily integrated in the house and can be connected to an existing boiler, for example.

Multiple Applications

The outdoor unit: this captures the free energy from the outdoor air and brings it into the house by means of the hydraulic module. These free calories are transported to the hydraulic module using an environmentally-friendly refrigerant gas with a high thermal exchange coefficient (R410A).

Via the hydraulic module, with control panel, the temperature inside the house can be controlled and efficiency maximised. It has a heat exchanger which transmits the calories contained in the refrigerant coming from the outdoor unit to the water used for the house’s heating and hot water.

The hydraulic module manages priorities in terms of heating and hot water production. It also has a 400 μm particle filter. This hydraulic module is situated in the house in the case of the split system or in the outdoor unit in the case of the single-unit system.

The hot water cylinder heats the hot water. It is made of stainless steel, which guarantees it a very long life. It is also fitted with a 3 kW element to ensure maximum comfort when outdoor temperatures are very low. The heater, situated at the top of the cylinder, guarantees maximum efficiency and faster heat-up. A 3-way valve for the hot water cylinder connection is supplied with the hot water cylinder

Other necessary or optional features (not provided by Panasonic):
- Room temperature thermostat, which can be connected to the Aquarea system to ensure optimum room temperature conditions.
- Solar kit, to connect solar panels for even greater efficiency.
 

Easy programming of the control panel

The primary circuit temperature is controlled based on the outdoor temperature.

The temperature of the primary circuit is determined by your heating specialist depending on your installation. Enter the below parameters in the remote control on starting up the system.

Your heating specialist must also select the type of operation you need: heating priority or hot water cylinder priority.

heating only models

BI-BLOC // HIGH-CONNECTIVITY // HEATING ONLY // SDF
SINGLE-PHASE THREE-PHASE
Indoor unit WH-SDF07C3E5 WH-SDF09C3E5 WH-SDF12C6E5 WH-SDF14C6E5 WH-SDF16C6E5 WH-SDF09C3E8 WH-SDF12C9E8 WH-SDF14C9E8 WH-SDF16C9E8
Heating Capacity at +7°C kW 7 9 12 14 16 9 12 14 16
COP at +7°C with heating water temperature at 35°C 4,4 4,09 4,67 4,5 4,23 4,74 4,67 4,5 4,23
Heating Capacity at -7°C kW 5,15 5,9 10 10,7 11,4 9 10 10,7 11,4
COP at -7°C 2,65 2,5 2,7 2,62 2,55 2,81 2,7 2,62 2,55
Heating Capacity at -15°C kW 4,6 5,9 8,9 9,5 10,3 8,3 8,9 9,5 10,3
COP at -15°C with heating water temperature at 35°C 2,3 2,2 2,43 2,35 2,33 2,55 2,43 2,35 2,33
Dimensions (H x W x D) mm 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353
Weight kg 43 43 49 49 49 50 51 51 51
Water pipe connector R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4
Pump No. of Speed 3 3 3 3 3 3 3 3 3
Input power(max) W 100 100 190 190 190 190 190 190 190
Heating water flow (_T=5 K. 35°C) l/min 20,1 25,8 34,4 40,1 45,9 25,8 34,4 40,1 45,9
Capacity of integrated electric heater kW 3 3 6 6 6 3 9 9 9
Input Power kW 1,59 2,2 2,57 3,11 3,78 1,9 2,57 3,11 3,78
Running and starting Current A 7,3 10,1 11,7 14,1 17,1 2,9 3,9 4,7 5,7
Maximum Current A 21 22,9 24 25 26 7,5 8,8 9,4 9,9
Outdoor unit WH-UD07CE5-A WH-UD09CE5-A WH-UD12CE5-A WH-UD14CE5-A WH-UD16CE5-A WH-UD09CE8 WH-UD12CE8 WH-UD14CE8 WH-UD16CE8
Sound pressure level dB(A) 48 49 50 51 53 49 50 51 53
Sound power level dB 66 67 67 68 70 66 67 68 70
Dimensions (H x W x D) mm 795 x 900 x 320 795 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320
Weight KG 66 66 106 106 106 109 109 109 109
Pipe Diameter Liquid mm (Inch) 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8")
Gas mm (Inch) 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8")
Refrigerant (R410A) kg 1,45 1,45 2,75 2,75 2,75 2,75 2,75 2,75 2,95
Pipe Length Range m 3 – 30 3 – 30 3 – 40 3 – 40 3 – 40 3 – 40 3 – 40 3 – 40 3 – 40
Pipe Length for nominal capacity m 7 7 7 7 7 7 7 7 7
Pipe Length for additional gas m 10 10 30 30 30 30 30 30 30
Additional Gas Amount (R410A) g/m 30 30 50 50 50 50 50 50 50
I/D&O/D Hight Difference m 20 20 30 30 30 30 30 30 30
Operation Range Outdoor Ambient °C –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35
Water Outlet (at-2/-7/-15) 2) °C 25 – 55 25 – 55 25 – 55 25 – 55 25 – 55 25 – 55 25 – 55 25 – 55 25 – 55

heating and cooling models

BI-BLOC // HIGH-CONNECTIVITY // HEATING AND COOLING // SDC
SINGLE-PHASE THREE-PHASE
Indoor unit WH-SDC07C3E5 WH-SDC09C3E5 WH-SDC12C6E5 WH-SDC14C6E5 WH-SDC16C6E5 WH-SDC09C9E8 WH-SDC12C9E8 WH-SDC14C9E8 WH-SDC16C9E8
Heating Capacity at +7°C kW 7 9 12 14 16 9 12 14 16
COP at +7°C with heating water temperature at 35°C 4,4 4,09 4,67 4,5 4,23 4,74 4,67 4,5 4,23
Heating Capacity at -7°C kW 5,15 5,9 10 10,7 11,4 9 10 10,7 11,4
COP at -7°C with heating water temperature at 35°C 2,65 2,5 2,7 2,62 2,55 2,81 2,7 2,62 2,55
Heating Capacity at -15°C kW 4,6 5,9 8,9 9,5 10,3 8,3 8,9 9,5 10,3
COP at -15°C with heating water temperature at 35°C 2,3 2,2 2,43 2,35 2,33 2,55 2,43 2,35 2,33
Cooling capacity at 35°C 6 7 10 11,5 12,2 7 10 11,5 12,2
EER at 35°C with cooling water temperature at 7/12°C 2,2 2,1 2,39 2,24 2,19 2,68 2,42 2,25 2,19
Dimensions (H x W x D) mm 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353
Weight kg 45 45 51 51 51 51 52 52 52
Water pipe connector R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4
Pump No. of Speed 3 3 3 3 3 3 3 3 3
Input power(max) W 75 75 190 190 190 190 190 190 190
Heating water flow (_T=5 K. 35°C) l/min 20,1 25,8 34,4 40,1 45,9 25,8 34,4 40,1 45,9
Capacity of integrated electric heater kW 3 3 6 6 6 3 9 9 9
Input Power kW 1,59 / 2,30 2,2 / 2,9 2,57 / 3,6 3,11 / 4,4 3,78 / 4,8 1,9 / 2,25 2,57 / 3,55 3,11 / 4,4 3,78 /4,8
Running and starting Current A 7,30 / 10,40 10,1 / 13,1 11,7 / 16,1 14,1 / 19,7 17,1 / 21,5 2,9 / 3,4 3,9 / 5,3 4,7 / 6,6 5,7 / 7,2
Maximum Current A 21 22,9 24 25 26 7,5 8,8 9,4 9,9
Outdoor unit WH-UD07CE5-A WH-UD09CE5-A WH-UD12CE5-A WH-UD14CE5-A WH-UD16CE5-A WH-UD09CE8 WH-UD12CE8 WH-UD14CE8 WH-UD16CE8
Sound pressure level dB(A) 48 49 50 51 53 49 50 51 53
Sound power level dB 66 67 67 68 70 66 67 68 70
Dimensions (H x W x D) mm 795 x 900 x 320 795 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320
Weight KG 66 66 106 106 106 109 109 109 109
Pipe Diameter Liquid mm (Inch) 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8")
Gas mm (Inch) 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8")
Refrigerant (R410A) kg 1,45 1,45 2,75 2,75 2,75 2,75 2,75 2,75 2,95
Pipe Length Range m 3 – 30 3 – 30 3 – 40 3 – 40 3 – 40 3 – 40 3 – 40 3 – 40 3 – 40
Pipe Length for nominal capacity m 7 7 7 7 7 7 7 7 7
Pipe Length for additional gas m 10 10 30 30 30 30 30 30 30
Additional Gas Amount (R410A) g/m 30 30 50 50 50 50 50 50 50
I/D&O/D Hight Difference m 20 20 30 30 30 30 30 30 30
Operation Range Outdoor Ambient °C –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35 –20 to 35
Water Outlet (at-2/-7/-15) 2) °C 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20

for more information please see link to Panasonic website below:

 http://www.panasonic.co.uk/html/en_GB/Products/Aquarea+-+Heating+and+hot+water+for+the+home/Introduction/7201334/index.html

Customer Reviews