Free Delivery on Orders Over £30
Prices Shown Include 20% UK VAT
Call Us On +44(0)1234 841221

Mitsubishi Heavy Industries SRF Floor HYPER Inverter Air Conditioning A++

Mitsubishi Heavy Industries Air Conditioning SRF50ZMX-S HYPER Inverter Floor Heat Pump 5kW/17000Btu

Mitsubishi Heavy Industries Air Conditioning SRF50ZMX-S HYPER Inverter Floor Heat Pump 5kW/17000Btu

£1,277.00 £1,064.17 (ex. VAT)
Stock Status: Sold Out
Sorry, this item is out of stock
Blog

MODEL REPLACED BY:

Mitsubishi Heavy Industries Air Conditioning SRC50ZSX-W2 SRF50ZSX-W Floor Heat Pump 5kW/18000Btu R32

Constant temperature and uniform air distribution 



MITSUBISHI HEAVY INDUSTRIES has made a giant leap forward in air conditioning and heat pump inverter technology, with the latest introduction of high performance SRF-ZMX  Floor Mounted air conditioning systems. The NEW ADVANCED SRF Floor Mounted Indoor Units are a new design with a flat/low profile flat appearance, and is very easy to keep clean. The SRF includes the Mitsubishi innovative NATURAL ENZYME FILTER which destroys funghi, bacteria and viruses. This, combined with the main Photocatalytic Washable Deodorizing Filter, provides healthy clean air for the occupants. The recently introduced SRF slim indoor unit has a reduced depth of 293mm, the new  multiple stage heat exchanger is folded to form a surround to the upper section of the fan enclosure. This ensures low air velocity, and reduced sound levels, whilst delivering high performance and efficiency. The unit produces an amazing 4.25 x input or 4250 watts for 1000 watt input.

Auto Air Outlet Selection:
 

In heating mode: Both lower and upper outlets operate with Auto fan speed WWW.ORIONAIRSALES.CO.UK: Cooling or Dry operation, both outlets will be kept for sixty minutes after the start or until room temperature is below the setting point. And then the air outlet will change to the upper outlet. That state will be maintained until switch is turned off. In case both outlets operation with Auto fan speed mode is selectedmode, the lower outlet will be kept for twenty minutes after the start or until room temperature is close to reaching the setting point. And then the air outlet will change to both outlets. That state will be maintained until the switch is turned off. Automatic adjustment of lower air outlet direction prevents stirring up of warm air and keeps optimum comfort at floor level.
 

In cooling mode: In case both lower and upper outlets operation is selected in WWW.ORIONAIRSALES.CO.UK: Cooling or Dry operation, both outlets will be kept for sixty minutes after the start or until room temperature is below the setting point. And then the air outlet will change to the upper outlet. That state will be maintained until switch is turned off. In case both outlets operation with Auto fan speed mode is selectedCooling or Dry operation, both outlets will be kept for sixty minutes after the start or until room temperature is below the setting point. And then the air outlet will change to the upper outlet. That state will be maintained until switch is turned off. In case both outlets operation with Auto fan speed mode is selected, the upper outlet will be kept for ten minutes after the start or until room temperature is close to reaching the setting point. And then the air outlet will change to both outlets in order to spread comfort air to every corner.

Product Key Feature's:


High CoP, up to 4.70
• New advanced technology control
• Infra-red controller with wall mounting bracket
• Reduced height slim construction
• Only 238mm deep

• Pipe runs up to 15 metres
Low noise – 26dBA
• Back-up switch for loss of controller
• Cold draft prevention on heat pump
start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for
up to 15 metres pipe length

Auto air direction with high and low air outlets for cooling/heating operations


Unit Data:


 

Indoor Unit Model

SRF 50 ZMX-S

Outdoor Unit Model

SRC 50 ZMX-S

Type

DC Inverter

Capacity (T=35°C)

Cooling

kW

5.00 (1.10~5.20)

Power Input (T=+35° C)

Cooling

kW

1.390 (0.20~1.70)

Annual Consumption

Cooling

kWh/a

292

Energy Efficiency Class Seasonal

Cooling

626/20111

A+

Energy Efficiency Class Seasonal Index

Cooling

SEER2

6.01

Energy Efficiency Rated

Cooling

EER3

3.60

Design load (Pdesignc)

Cooling

kW

5.00

Capacity (T=+7° C)

Heating

kW

6.00 (0.60~6.90)

Power Input (T=7° C)

Heating

kW

1.540 (0.20~2.15)

Annual Consumption

Heating

kWh/a

1736

Energy Efficiency Class Seasonal

Heating

626/20111

A+

Energy Efficiency Class Seasonal Index

Heating

SCOP2

4.19

Energy Efficiency Rated

Heating

COP3

3.90

Design load (Pdesignh) @-10°C

Heating

kW

5.20

T° operational limit (Tol)

Heating

°C

-15

Power supply

Ph-V-Hz

1-220~240V-50HZ

I.U. ~ O.U.

O.U.

Input Rated Current (Cooling - Heating)

A

6.4 - 7.1

Wiring cables i.u./o.u. (without ground)

nb.

3

Refrigerant Pipe Liquid/Gas side

mm (inch.)

6.35 (1/4”) - 12.7 (1/2”)

Max splitting distance I.U./O.U.

m

30

Max splitting level difference (O.U./I.U.-I.U./O.U.)

m

20/20

Refrigerant Precharge

Kg

1.50

MAX Splitting without Refrigerant Precharge

m

15

Refrigerant Precharge

g/m

20

Temperature range cooling

°C

-15°C~+43°C

Temperature range heating

°C

-15°C~+21°C

Indoor unit

Dimensions (HxWxD)

mm

600x860x238

Net weight

Kg

19

Indoor Noise level 1 m (Hi/Mi/Lo)

dB(A)

46

Power sound level

dB(A)

58

Indoor air flow (Hi/Mi/Lo)

m3/h

690

Drain hose diameter

mm

16

Remote control (st. equipment)

type

Infrared remote control

Filter (st. equipment)

1x

Natural enzyme filter

Filter (st. equipment)

1x

Photocatalytic

Outdoor Unit

Dimensions (HxWxD)

mm

640x800(+71)x290

Net weight

Kg

45

Max noise level 1 m

dB(A)

54

Power sound level

dB(A)

63

Max air flow

m3/h

2400

Interface for wired remote control &/or SC-ADNA-E (optional)

SC-BIKN-E

Wired remote control (optional)

RC-E5 / RC-EX1A

SUPERLINK II Interface (optional)

SC-ADNA-E


PDF Data:


http://www.orionairsales.co.uk/ekmps/shops/orionair/resources/Design/pdf-download-image.jpg 





These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.

Write an online review and share your thoughts with other shoppers!
Be the first to review this product