Power Inverter Heat Pump
Mitsubishi Electric Mr Slim PKA-RP50GAL (5kW / 17000 Btu) designed for applications with long piperuns. The PKA50GAL inverter can do 50 Meters piperun while delivering 5 Kw of power. These systems can reuse existing pipework even if the pipe was using old R22 or R407c Refrigerants. |
Advanced inverter technology makes the Mr Slim Power Inverter the number one choice for improving comfort. They provide energy savings of up to 70% annually when compared to a previous non-inverter model. Operating noise has also been reduced thanks to improvements in fan design, while existing pipe work is reusable for easier maintenance and installation. |
Product Key Feature's
• High CoP, up to 3.41
• Advanced technology control
• Infra-red controller with wall mounting bracket
• Slim construction
• Pipe runs up to 50 metres
• Low noise – 39dBA
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 30 metres pipe length
• Old pipework can be reused.
Technical Data
PKA-RP50FAL2 Indoor Unit
| Capacity (kW): |
|
| Heating (Nominal) (Low - High) |
6.00 (2.50 - 7.30) |
| Cooling (Nominal) (Low - High) |
5.00 (2.30 - 5.60) |
| Heating (UK) (Low - High) |
5.10 (2.15 - 6.20) |
| Cooling (UK) (Low - High) |
4.50 (2.05 - 5.05) |
| SHF R410A (Nominal) |
0.86 |
| COP / EER (Nominal) |
3.41 / 3.01 |
| Energy Label Heating / Cooling |
B / B |
| Width - mm |
1400 |
| Depth - mm |
235 |
| Height - mm |
340 |
| Weight - kg |
24 |
| Airflow (m3/min) - Lo-Hi |
15-20 |
| Noise (dBA) - Lo-Hi |
39-45 |
| Pipe Size Gas mm (in) |
12.7 (1/2) |
| Pipe Size Liquid mm (in) |
6.35 (1/4) |
| Electrical Supply |
Fed by outdoor unit |
| Phase |
Single |
| Fuse Rating (BS88) - HRC (A) |
6 |
| Interconnecting Cable No. Cores |
4 |
PUHZ-RP50VHA2 Outdoor Unit
| Width - mm |
800 |
| Depth - mm |
300 + 23 |
| Height - mm |
600 |
| Weight - kg |
45 |
| Noise (dBA) (Heating / Cooling) |
46 / 44 |
| Electrical Supply |
220-240v, 50Hz |
| Phase |
Single |
| Fuse Rating (BS88) - HRC (A) |
16 |
| System Power Input (kW) - Heating (Nominal) |
1.76 |
| System Power Input (kW) - Cooling (Nominal) |
1.66 |
| System Power Input (kW) - Heating (UK) |
1.57 |
| System Power Input (kW) - Cooling (UK) |
1.41 |
| Starting Current (A) |
5 |
| System Running Current (A) - Heating / Cooling |
6.9 / 6.59 |
| Mains Cable No. Cores |
3 |
| Max Pipe Length (m) |
50 |
| Max Height Difference (m) |
30 |
| Charge (kg) - 30m |
2.5 |
|