A Energy Rated Product    
 

The Hitachi air conditioning RAD Ducted range are economical and environmentally friendly. Using the latest compressor and inverter technology keeps power consumption to a minimal, but at the same time providing powerful cooling and heating. All Hitachi’s air conditioning units offer high seasonal efficiencies, achieving high seasonal performance SCOP B 3.8 and SEER A 4.8. ​​The dimensions of the model (270x900x720) allow for easier integration into ceiling and loft spaces.
 
Enhanced inverter performance and system performance are achieved by the addition of a ‘Direct Current’ drive compressor, resulting in up to 10% more efficient than standard 'AC' (Alternating Current) Systems. The variable speed compressor (inverter) enables the system to rapidly reach the desired room temperature setting. Once the desired room temperature has been achieved the compressor rotation peed is reduced, saving up to 30% in energy usage (when compared to standard fixed speed systems).

 
This unit is ductable, meaning airflow can be ducted to another area in the room or another smaller areas, the unit has its own internal drain pump to remove accumulated condensation water from the drain pan even while it is operating. A float switch monitors the water level and automatically activates the pump as necessary. High Stream turbo fans with curved blades for 20% increased efficiency with noise levels as low as 28dB(A)

 
Volt Free control of the air conditioning system option, used to turn the unit on/off remotely after receiving a signal such as key-card, door or window switch, specifically useful in hotel rooms to prevent unnecessary use. Accessory SPX WDC3 is required.
 

                                                                                                                      
Product Key Feature's:

 

  • High CoP, up to record 3.8
  • Infra-red controller
  • Slim construction 270mm
  • Pipe runs up to 20 meters
  • Low noise 28dBA on low
  • Cold draft prevention on heat pump start up
  • Fault diagnosis
  • Auto re-start after power interruption
  • PRE-CHARGED WITH REFRIGERANT for up to 7.5 metres pipe length
  • Light weight noise absorbing outdoor unit
  • This unit is also Ductable (Air flow can be ducted into other areas)



 


RAD Ducted RAD-70PPA

 
RAD-70PPA
Nominal Cooling Capacity (min-max) kW 7.10 (0.90-8.00)
Sensible Cooling Capacity kW 5.1
UK Cooling Capacity (sensible) kW 6.5 (4.6)
Nominal Heating Capacity  (min-max) kW 8.00 (0.9-9.00)
Nominal Cooling Power Input (min-max) kW 2.53 (0.20-2.92)
Nominal Heating Power Input (min-max) kW 2.34 (0.20-3.10)
Seasonal Efficiency  SEER 4.8
Energy Efficiency Class B
Seasonal Efficiency (Average Climate) SCOP 3.8
Energy Efficiency Class B
Nominal Load Efficiency EER/COP 2.81/3.42
Energy Class (cool/heat) A/B
Noise Level Cooling (Sound Pressure) (SL/L/M/H) dB(A) 28/30/32/35
Noise Level Heating (Sound Pressure) (SL/L/M/H) dB(A) 29/31/33/36
Noise Level (Sound Power) dB(A) 61
Air Flow Cooling Mode (SL/L/M/H) m³/h 618/660/780/960
Air Flow Heating Mode (SL/L/M/H) m³/h 618/660/780/960
Static Pressure (SL/L/M/H) Pa -/30/50/80
Dehumidification l/hr 5.2
Dimensions HxWxD mm 270x900x720
Weight kg 35.0
Drain Pump Yes, Included
Power Supply 35V DC & 230V / 1Ph / 50Hz
Drain Diameter (ext) Ø16mm
Remote Control Wired SPX-RCDA
Infra-Red SPX-RCKA
Outdoor Unit RAC-70DPA
Noise Level Cooling (Sound Pressure) Night Mode dB(A) 53
Noise Level Heating (Sound Pressure) Night Mode dB(A) 55
Noise Level (Sound Power) dB(A) 67
Air Flow (Cooling/Heating) m³/h 2820/2820
Dimensions HxWxD mm 800x850x298
Weight kg 55.0
Piping Diameter (Liquid/Gas) Inch 1/4 - 5/8
mm 6.35 - 15.88
Minimum Pipe Length m 5.0
Maximum Pipe Length m 20
Maximum Height Difference m 20
Current Quantity of Refrigerant kg 1.80
Chargeless/Additional Refrigerant m / g/m 30 / -
Power Supply AC 230V / 1Ph / 50Hz
Recommended Fuze Size A 30
Starting Current A 10.0
Running Current (Cooling/Heating) A 11.60-10.70/10.70-9.80
Interconnecting Cables No. 2 (Screened) 2 +E
Working Range (Cooling/Heating) °C -10-43 / -15-21
Refrigerant / GWP R410A / 1975
Compressor Type Twin Rotary



PDF Data:



          


These air conditioning units must be installed by an F-Gas qualified engineer.  We can install the unit for you using our F-Gas Certified Engineers. Please note if you do not select our installation service  we will not ship the unit until we have obtained evidence from you that you will have the unit installed by an F-Gas qualified engineer. This is a requirement of the Article 11 (5) EC/517/2014 on fluorinated greenhouse gases and The Fluorinated Greenhouse Gases Regulations 2015.