UA-3499030

+44 (0)845 567 70 80

Add Your Email to Revieve OurSpecial offers
Items : 0
Total : £0.00
Safe and SecureOnline Ordering

Skype Me™!

Skype us at orionairsales

All Prices Include VAT at 20%

Great Value, 128bit secure purchasing. Buy now with safety.

Air Conditioning Installation Manual

All In One Installation Manual

Inverters

Mitsubishi Electric Super High COP Inverter Heat-pump Air Conditioning unit

Portable Server Room Air Conditioning Unit

Pro Audio Equipment

Worcester Hot Water SolarPanel Collector Roof Installation Package

Wind Turbine Kits

Mitsubishi SRK20ZIX AIR TO AIR Heat pump with 5.45 C.O.P

Air Conditioning Information

ECA Capital Allowance for business

Special Offers

Daikin Wall Air Conditioning

Solar PV Panels

Wind Turbine

Air Source Heat-pump heating systems

Wall Air conditioning

Mitsubishi Heavy Industries Air to water heat pump

The New LG Air to water heat pump

Mitsubishi Heavy Industries Air conditioning

Mitsubishi Electric Air conditioning

The new Mitsubishi SRF HYPER Inverter Floor Air Conditioning

Ice makers

Self Install / DIY Air Conditioning

Portable Air Conditioning

Conservatory Air Conditioning

Hailea Water-Chiller HC150A 165 Watt / 150 Litre Cooling Capacity

Dehumidifiers

Portable Air Conditioning

Heat Screen Air Curtain RM125-12-D/Y-A (7.2kw/25000Btu) 1200mm

Conservatory Air Conditioning

EFOY Fuel Cell Generator

Danfoss Compressor

L'Unite Compressor

L'Unit Hermetique Condensing Units

Tecumseh Compressor

LG Air Conditioning

Aspera Compressor

Copeland Compressor

Portable Air Conditioner Midear MPF-12CEN2 (3.5 kW / 12000 Btu) SPECIAL OFFER

Air Conditioning

AGM Batteries

Gel Batteries

Daikin air conditioning FLXS25B wall mounted (2.5 kW / 9000 Btu) Heat Pump

Our Price: £1,025.00
Daikin air conditioning FLXS25B wall mounted
Daikin air conditioning FLXS25B wall mounted
Daikin air conditioning FLXS25B wall mounted
Daikin air conditioning FLXS25B wall mounted
Description

Daikin air conditioning FLXS25B flexi ceiling / wall mounted inverter (2.5 kW / 9000 Btu)

  • Can fit on either ceiling or lower wall; its low height enables the unit to fit beneath a window
  • Outdoor units for pair application
  • Home leave operation maintains the indoor temperature at your specified comfort level during absence, thus saving energy
  • Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency
  • Night set mode saves energy by preventing overcooling or overheating during night time
  • Outdoor unit silent operation: "silent" button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood.
  • Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall
  • Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.
  • Whisper quiet operation: down to 28dBA sound pressure level
  • Indoor unit silent operation: "silent" button on the remote control lowers the operation sound of the indoor unit by 3dBA
  • Photocatalytic deodorising air purification filter deodorises the air, powerfully decomposes odours, removes house dust and pollen and helps to prevent bacterial and viral propagation to ensure a steady supply of clean air
  • Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room
 

Cooling capacity Min. kW 1.2
  Min. Btu/h 4,100
  Min. kcal/h 1,030
  Nom. kW 2.5 (1)
  Nom. Btu/h 8,500 (1)
  Nom. kcal/h 2,150 (1)
  Max. kW 3.0
  Max. Btu/h 10,200
  Max. kcal/h 2,580
Heating capacity Min. kW 1.2
  Min. Btu/h 4,100
  Min. kcal/h 1,030
  Nom. kW 3.4 (2)
  Nom. Btu/h 11,600 (2)
  Nom. kcal/h 2,920 (2)
  Max. kW 4.5
  Max. Btu/h 15,400
  Max. kcal/h 3,870
Power input Cooling Min. kW 0.30
    Nom. kW 0.65
    Max. kW 0.86
  Heating Min. kW 0.29
    Nom. kW 0.98
    Max. kW 1.49
EER 3.85
COP 3.47
Energy label Cooling A
  Heating B
Annual energy consumption kWh 325
Notes Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m

  FLXS25BAVMB  

Productname FLXS25BAVMB
 
Casing Colour Almond white
Dimensions Unit Height mm 490
    Width mm 1,050
    Depth mm 200
Weight Unit kg 16
Fan Air flow rate Cooling High m³/min 7.6
      Nom. m³/min 6.8
      Low m³/min 6.0
      Silent operation m³/min 5.2
    Heating High m³/min 9.2
      Nom. m³/min 8.3
      Low m³/min 7.4
      Silent operation m³/min 6.6
Sound power level Cooling High dBA 53
  Heating High dBA 53
Sound pressure level Cooling High dBA 37
    Nom. dBA 34
    Low dBA 31
    Silent operation dBA 28
  Heating High dBA 37
    Nom. dBA 34
    Low dBA 31
    Silent operation dBA 29
Piping connections Liquid OD mm 6.35
  Gas OD mm 9.52
  Drain 18
Standard Accessories Item Installation and operation manual
  Quantity 1
  Item Infrared remote control
  Quantity 1
  Item Batteries
  Quantity 2
  Item Remote control holder
  Quantity 1
  Item Air purification filter
  Quantity 1
  Item Heat insulation tube (refrigerant pipe)
  Quantity 1
  Item Mounting plate
  Quantity 1
  Item Side cover
  Quantity 2
  Item Binding band
  Quantity 4
  Item Photocatalytic deodorizing filter
  Quantity 1
Power supply Name VM
  Phase 1~
  Frequency Hz 50/60
  Voltage V 220-240/220-230
Notes 220V
230V
240V
Sound values are measured in an anechoic room.
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
The sound power level is an absolute value indicating the power which a sound source generates.


RXS25G2V1B  

Productname RXS25G2V1B
 
Dimensions Unit Height mm 550
    Width mm 765
    Depth mm 285
Weight Unit kg 34
Compressor Type Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB -10
      Max. °CDB 46
  Heating Ambient Min. °CWB -15
      Max. °CWB 20
Sound power level Cooling Nom. dBA 61
Sound pressure level Cooling High dBA 46
    Low dBA 43
  Heating High dBA 47
    Low dBA 44
Refrigerant Type R-410A
Piping connections Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
  Level difference IU - OU Max. m 15.0
Standard Accessories Item Installation manual
  Quantity 1
Power supply Phase 1~
  Frequency Hz 50
  Voltage V 220-230-240